Datasheet
XMC1100
XMC1000 Family
Electrical Parameter
Data Sheet 45 V1.4, 2014-05
3.3.7 Peripheral Timings
Note: These parameters are not subject to production test, but verified by design and/or
characterization.
3.3.7.1 Synchronous Serial Interface (USIC SSC) Timing
The following parameters are applicable for a USIC channel operated in SSC mode.
Note: Operating Conditions apply.
Table 23 USIC SSC Master Mode Timing
Parameter Symbol Values Unit Note /
Test Condition
Min. Typ. Max.
Slave select output SELO
active to first SCLKOUT
transmit edge
t
1
CC 80 −− ns
Slave select output SELO
inactive after last
SCLKOUT receive edge
t
2
CC 0 −− ns
Data output DOUT[3:0]
valid time
t
3
CC -10 − 10 ns
Receive data input
DX0/DX[5:3] setup time to
SCLKOUT receive edge
t
4
SR 80 −− ns
Data input DX0/DX[5:3]
hold time from SCLKOUT
receive edge
t
5
SR 0 −− ns
Table 24 USIC SSC Slave Mode Timing
Parameter Symbol Values Unit Note /
Test Condition
Min. Typ. Max.
Select input DX2 setup to
first clock input DX1 transmit
edge
1)
t
10
SR 10 −− ns
Select input DX2 hold after
last clock input DX1 receive
edge
1)
t
11
SR 10 −− ns
Subject to Agreement on the Use of Product Information