Datasheet

XMC1100
XMC1000 Family
Electrical Parameter
Data Sheet 46 V1.4, 2014-05
Receive data input
DX0/DX[5:3] setup time to
shift clock receive edge
1)
t
12
SR 10 −− ns
Data input DX0/DX[5:3] hold
time from clock input DX1
receive edge
1)
t
13
SR 10 −− ns
Data output DOUT[3:0] valid
time
t
14
CC - 80 ns
1) These input timings are valid for asynchronous input signal handling of slave select input, shift clock input, and
receive data input (bits DXnCR.DSEN = 0).
Table 24 USIC SSC Slave Mode Timing (cont’d)
Parameter Symbol Values Unit Note /
Test Condition
Min. Typ. Max.
Subject to Agreement on the Use of Product Information