Datasheet

C167CR
C167SR
General Device Information
Data Sheet 16 V3.3, 2005-02
Note: The following behavioural differences must be observed when the bidirectional
reset is active:
Bit BDRSTEN in register SYSCON cannot be changed after EINIT and is cleared
automatically after a reset.
The reset indication flags always indicate a long hardware reset.
The PORT0 configuration is treated as if it were a hardware reset. In particular, the
bootstrap loader may be activated when P0L.4 is low.
•Pin RSTIN
may only be connected to external reset devices with an open drain output
driver.
A short hardware reset is extended to the duration of the internal reset sequence.
V
DD
17, 46,
56, 72,
82, 93,
109,
126,
136,
144
Digital Supply Voltage:
+ 5 V during normal operation and idle mode.
2.5 V during power down mode.
V
SS
18, 45,
55, 71,
83, 94,
110,
127,
139,
143
Digital Ground.
Table 2 Pin Definitions and Functions P-MQFP-144-8 (cont’d)
Symbol Pin
No.
Input
Outp.
Function