Datasheet

TLE 4207
Data Sheet 8 2000-12-05
Outputs OUT1-2
Saturation Voltages
Source (upper)
I
OUT
= 0.2 A
V
SAT U
0.85 1.15 V T
j
= 25 °C
Source (upper)
I
OUT
= 0.4 A
V
SAT U
0.90 1.20 V T
j
= 25 °C
Sink (upper)
I
OUT
= 0.8 A
V
SAT U
1.10 1.50 V T
j
= 25 °C
Sink (lower)
I
OUT
= 0.2 A
V
SAT L
0.15 0.23 V T
j
= 25 °C
Sink (lower)
I
OUT
= 0.4 A
V
SAT L
0.25 0.40 V T
j
= 25 °C
Sink (lower)
I
OUT
= 0.8 A
V
SAT L
0.45 0.75 V T
j
= 25 °C
Total Drop I
OUT
= 0.2 A V
SAT
11.4V
V
SAT
= V
SAT U
+ V
SAT L
Total Drop I
OUT
= 0.4 A V
SAT
1.2 1.7 V
V
SAT
= V
SAT U
+ V
SAT L
Total Drop I
OUT
= 0.8 A V
SAT
1.6 2.5 V
V
SAT
= V
SAT U
+ V
SAT L
Clamp Diodes
Forward voltage; upper
V
FU
11.5VI
F
= 0.4 A
Upper leakage current
I
LKU
––5mAI
F
= 0.4 A
1)
Forward voltage; lower V
FL
0.9 1.4 V I
F
= 0.4 A
Notes see page 10.
Electrical Characteristics (contd)
8 V <
V
S
< 18 V; INH = High; I
OUT1-2
= 0 A; 40 °C < T
j
< 150 °C;
unless otherwise specified
Parameter Symbol Limit Values Unit Test Condition
min. typ. max.