Datasheet
BTS711L1
Semiconductor Group 9 2003-Oct-01
Open-load detection, OUT1...4
ON-state diagnostic condition:
V
ON
< R
ON
·I
L(OL)
; IN high
Open load
detection
Logic
unit
+ V
bb
OUT
ON
V
ON
OFF-state diagnostic condition:
V
OUT
> 3 V typ.; IN low
Open load
detection
Logic
unit
V
OUT
Signal GND
R
EXT
R
O
OFF
GND disconnect
(channel 1/2 or 3/4)
PROFET
V
IN2
ST
OUT2
GND
bb
V
bb
I
bb
IN1
OUT1
V
IN1
V
IN2
V
ST
V
GND
Any kind of load. In case of IN = high is V
OUT
≈ V
IN
- V
IN(T+)
.
Due to V
GND
> 0, no V
ST
= low signal available.
GND disconnect with GND pull up
(channel 1/2 or 3/4)
PROFET
V
IN2
ST
OUT2
GND
bb
V
bb
IN1
OUT1
V
IN1
V
IN2
V
ST
V
GND
Any kind of load. If V
GND
> V
IN
- V
IN(T+)
device stays off
Due to V
GND
> 0, no V
ST
= low signal available.
V
bb
disconnect with energized inductive
load
PROFET
V
IN2
ST
OUT2
GND
bb
V
bb
IN1
OUT1
high
For an inductive load current up to the limit defined by E
AS
(max. ratings see page 3 and diagram on page 10) each
switch is protected against loss of V
bb
.
Consider at your PCB layout that in the case of Vbb dis-
connection with energized inductive load the whole load
current flows through the GND connection.