User's Manual

InfiNet Wireless R5000 Technical User Manual
Copyright © 2004-2011 by InfiNet Wireless
54
Indicator panel:
How to use:
Turning on:
1. For turning InfiNet Wireless RapidView-1 on simply push «Power button».
2. Device LEDs will light up for 2 seconds.
3. Device will perform constant tries to connect to ODU. If devices power is
normal Power/ODU connection LED (1) will blink 1 time per second. If
devices power is low LED 1 will blink 4 times per second in turn with not
lighting intervals.
4. Once ODU link is established LED 1 stops blinking (if power is normal) and
devices interfaces status are shown by LEDs 2-6.
5. 1 time per second device updates its status output.
6. If ODU link will be broken LEDs 2-6 will go out after 2 seconds and LED 1
will start blinking 1 time per second.
Diagnostic device connection to ODU should be done via console port of the
ODU. Once link is up between ODU and diagnostic device the following record is
put in ODU system log:
Connected test unit. Begin service communication over console.
Test unit detected: rf0 rf5.0
Exact radio interface names depend on wireless equipment configuration.
When diagnostic device is unplugged from the following record is put in ODU
system log:
Test unit disconnected. Return to normal console mode.
LEDs modes description:
ODU status monitoring via diagnostic device is performed by its LEDs indication.
LEDs modes and ODU status correspondence is shown in the following table: