19 Figure - Cable loop
6.4.3.2 AUX-ODU-LPU-GCable Gland Assembly
In order to ensure that the cable gland remains sealed under any environmental conditions, please, follow the
assembly sequence according to the procedure below:
Step 1: Insert the sealing insert into the clamping claw.
Step 2: Assemble the cable gland by putting the thread-lock sealing nut, clamping claw with sealing insert
and body onto the cable as shown on the figure.
Step 3: Insert the clamping claw with sealing insert into the body as shown on the figure.
Step 4: Crimp the standard RJ-45 connector onto the cable using crimping tool.Pin-out scheme: T568B
wiring standards.
Step 5: Insert the Rj-45 connector into the correspondingsocket until you hear a click.
Step 6: Screw the cable gland body into the port and tighten it.Do not apply excessive force.
Step 7: Tighten thethread-lock sealing nut.Do not apply excessive force.
CAUTION
Missing or bad grounding may leave the unit vulnerable to lightning damage.
CAUTION
Make sure that the RJ-45 connector is well-crimped. A loose connector can damage the device. Please note