User Manual
Table Of Contents
- About This Manual
- Important Notice
- Introduction
- Document structure
- Document marks
- Key Features
- Hardware Platform
- Power supply
- Lightning protection unit
- Packing List
- Planning considerations
- Link Pre-configuration in the lab
- Installation
- Operation & Administration
- Web GUI Access
- Dashboard
- Device status
- Wired interface
- Wireless link status
- Modulation code scheme
- Modulation and coding schemes are selected independently for each channel (uplink and downlink) for both polarizations. Current modulation for each channel is displayed in the MCS subsection.
- Received signal strength indicator
- EVM
- Retries and Frame loss
- General settings
- Security settings
- Radio settings
- Network settings
- Switch Settings
- SNMP settings
- Spectrum Analyzer
- Antenna Alignment Tool
- Maintenance
- Instant DFS
- Troubleshooting
- Glossary
Infinet Wireless: Technical Documentation – Quanta 5 / Quanta 6
Troubleshooting – 107
8.3.2 Checking the switch settings on the remote device
Further diagnostics should be performed at the device installation site. Try to access the device directly using the
ERConsole utility.
When accessing the web interface, in the "Switch" section, make sure the VLAN-based switching settings are
configured in accordance with the network architecture. Make sure the connectivity between the "ge0", "radio" and
"mgmt" interfaces is enabled in a connectivity matrix.
In the "Network" section, make sure the correct VLAN ID is assigned to the management IP address and the default
gateway is configured in accordance with network architecture.