User Manual

Table Of Contents
Infinet Wireless: Technical Documentation – Quanta 5 / Quanta 6
Introduction– 27
Parameter Description
Ethernet
Connectors Pin-
out
ETH
IN
Pin 1 2 3 4 5 6 7 8
Descript
ion
Data
pair
A+
Data
pair
A-
Data
pair
B+
Data
pair
C-
Data
pair
C+
Data
pair
B-
Data
pair
D+
Data
pair
D-
ETH
OUT
Pin 1 2 3 4 5 6 7 8
Descript
ion
Data
pair
A+
Data
pair
A-
Data
pair
B+
+VDC
+ Data
pair
C-
+VDC +
Data
pair
C+
Data
pair
B-
-VDC +
Data
pair
D+
-VDC +
Data
pair
D-
Lightning
Protection
In compliance with:
GR-1089
IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
ETSI ETS 300 386
4 Table - AUX-ODU-INJ-G Specifications
3.5.5.1 Packing List
3.6 Lightning protection unit
AUX-ODU-LPU-L(see page 28)
AUX-ODU-LPU-G(see page 29)
CAUTION
Using inappropriate DC source will damage the ODU, which will be not covered by warranty