User Manual

Table Of Contents
Infinet Wireless: Technical Documentation – Quanta 5 / Quanta 6
Link Pre-configuration in the lab– 38
1.
2.
3.
4.
5.
1.
2.
3.
5 Link Pre-configuration in the lab
Usually, before going into the field, it is recommended to pre-configure in the lab the Infinet Wireless units to verify
the link establishment. Therefore, let's take the units to be used for this course out of the package and place them
on the table.
5.1 Step 1: Connection scheme
The equipment list required for the lab configuration:
Outdoor units - 2 pcs.
Power supply - 2 pcs.
Power cord - 2 pcs.
Ethernet cables - 4 pcs.
Laptop with Ethernet port available.
We will perform the settings mentioned below for each unit of the link andcheck if wireless link was established
correctly.
Use the following instruction to assemble a test scheme:
Connect Gigabit Ethernet portat the ODU to the power supply port labeled as "OUT".
Connect Ethernet portat the laptop to the power supply port labeled as"IN".
Connect the power cord to power supply and plug it to AC mains.
NOTE
A minimum set of requirements must be met during devices pre-configuration in the lab:
Make sure the devices are not directed at each other in order to prevent radio modules damage.
A minimum transmit output power must be set.
In case of two devices with external antennas,it is recommended to connect them in the link
directly, with RF cables and RF attenuators with attenuation of at least 40 dB for each polarization
(installation\deinstallation of the RF attenuators and RF cables should only be performed when the
devices are switched off).