User Manual
Table Of Contents
- About This Manual
- Important Notice
- Introduction
- Document structure
- Document marks
- Key Features
- Hardware Platform
- Power supply
- Lightning protection unit
- Packing List
- Planning considerations
- Link Pre-configuration in the lab
- Installation
- Operation & Administration
- Web GUI Access
- Dashboard
- Device status
- Wired interface
- Wireless link status
- Modulation code scheme
- Modulation and coding schemes are selected independently for each channel (uplink and downlink) for both polarizations. Current modulation for each channel is displayed in the MCS subsection.
- Received signal strength indicator
- EVM
- Retries and Frame loss
- General settings
- Security settings
- Radio settings
- Network settings
- Switch Settings
- SNMP settings
- Spectrum Analyzer
- Antenna Alignment Tool
- Maintenance
- Instant DFS
- Troubleshooting
- Glossary
Infinet Wireless: Technical Documentation – Quanta 5 / Quanta 6
Link Pre-configuration in the lab– 39
•
•
•
5.2 Step 2: Access to the device
Let's access each unit to the default IP address 10.10.10.1 with mask 255.255.255.0 via a web browser. Before, make
sure the Ethernet port of the Laptop has anIP address assigned from the same subnetwork as the one for the unit
(e.g., set 10.10.10.10 with mask 255.255.255.0).
Use any letters or numbers for the initial authentication on each unit, for example:
Login: login.
Password: password.
After the first login, let's configure a distinctive name for each unit and set a custom login and password. Go to the
"Settings" → "General" section and configure:
Device Name (e.g., Master/Slave).
NOTE
We assume that each unit used in this setup has not been configured before and runs with the factory
settings.
NOTE
We strongly recommend to change your login and password after the first login.