User Manual
Table Of Contents
- About This Manual
- Important Notice
- Introduction
- Document structure
- Document marks
- Key Features
- Hardware Platform
- Power supply
- Lightning protection unit
- Packing List
- Planning considerations
- Link Pre-configuration in the lab
- Installation
- Operation & Administration
- Web GUI Access
- Dashboard
- Device status
- Wired interface
- Wireless link status
- Modulation code scheme
- Modulation and coding schemes are selected independently for each channel (uplink and downlink) for both polarizations. Current modulation for each channel is displayed in the MCS subsection.
- Received signal strength indicator
- EVM
- Retries and Frame loss
- General settings
- Security settings
- Radio settings
- Network settings
- Switch Settings
- SNMP settings
- Spectrum Analyzer
- Antenna Alignment Tool
- Maintenance
- Instant DFS
- Troubleshooting
- Glossary
Infinet Wireless: Technical Documentation – Quanta 5 / Quanta 6
Installation– 48
•
•
•
•
•
•
•
•
•
•
6.2.1 Assemble procedure
In order to ensure that the device case remains sealed under any environmental conditions follow the assemble
procedure:
Step 1: Insert the sealing insert into the clamping claw.
Step 2: Assemble the cable gland by putting the thread-lock sealing nut, clamping claw with sealing insert
and body onto the cable as shown on the figure.
Step 3: Insert the clamping claw with sealing insert into the body as shown on the figure.
Step 4: Crimp the standard RJ-45 connector onto the cable using crimping tool.Pin-out scheme: T568B
wiring standards
Step 5: Insert the Rj-45 connector into the device socket until you hear a click.
Step 6: Screw the cable gland body into the port and tighten it.Do not apply excessive force.
Step 7: Tighten thethread-lock sealing nut.Do not apply excessive force.
6.3 Mounting
Pre-installation
Reqiered tools
Screwdriwer set.
Pliers / pipe wrench.
Wrench set.
Additional equipment
NOTE
Do not use the shielded RJ-45 connector on this end of the cable as it should be attached on the power
supply unit end.
CAUTION
Make sure that the RJ-45 connector is well-crimped. A loose connector can damage the device. Please note
that such damage is not covered by the warranty.