User Manual
Table Of Contents
- About This Manual
- Important Notice
- Introduction
- Document structure
- Document marks
- Key Features
- Hardware Platform
- Power supply
- Lightning protection unit
- Packing List
- Planning considerations
- Link Pre-configuration in the lab
- Installation
- Operation & Administration
- Web GUI Access
- Dashboard
- Device status
- Wired interface
- Wireless link status
- Modulation code scheme
- Modulation and coding schemes are selected independently for each channel (uplink and downlink) for both polarizations. Current modulation for each channel is displayed in the MCS subsection.
- Received signal strength indicator
- EVM
- Retries and Frame loss
- General settings
- Security settings
- Radio settings
- Network settings
- Switch Settings
- SNMP settings
- Spectrum Analyzer
- Antenna Alignment Tool
- Maintenance
- Instant DFS
- Troubleshooting
- Glossary
Infinet Wireless: Technical Documentation – Quanta 5 / Quanta 6
Installation– 53
•
•
•
•
General recommendations for installations of lightning protection units:
Install the lightning protection unit on both ends of the cable to protect both the outdoor and the indoor
unit.The purpose of theLPUat the top is to protect theODUfrom a surge of lightning strike which can hit
the long FTP cablerun along the height of the pole or on the roof of the building.The purpose of theLPUat
the bottom is to protect theIDUand customer equipment.
Use the lightning protection unit to protect all circuits for signal transmission and power supply (video,
audio, management signals, Ethernet, etc.)
Regularly (especially before the periods with high thunderstorm activity) check the integrity of lightning
protection units, grounding elements andbonding conductors.
The ports of the AUX-ODU-LPU-L device are symmetrical, i.e. the correspondence of ports position to the
external unit and the power supply does not matter.
Make sure to install the twoLPUdevices as shown in the scheme below.
13 Figure - Connection scheme
6.4.2.1 AUX-ODU-LPU-L Mounting
AUX-ODU-LPU-Lis installed on a mast, using clamp. Attach the grounding cable (min cross-section 2.5 mm
2
) to the
case, using grounding bolt.
CAUTION
Please note grounding cables should not be connected to the mast. All devices must use separate
grounding cable that should be connected to the grounding circuit. The best scenario is when grounding
cables are lined parallel to the Ethernet cable.