User Manual
Table Of Contents
- About This Manual
- Important Notice
- Introduction
- Document structure
- Document marks
- Key Features
- Hardware Platform
- Power supply
- Lightning protection unit
- Packing List
- Planning considerations
- Link Pre-configuration in the lab
- Installation
- Operation & Administration
- Web GUI Access
- Dashboard
- Device status
- Wired interface
- Wireless link status
- Modulation code scheme
- Modulation and coding schemes are selected independently for each channel (uplink and downlink) for both polarizations. Current modulation for each channel is displayed in the MCS subsection.
- Received signal strength indicator
- EVM
- Retries and Frame loss
- General settings
- Security settings
- Radio settings
- Network settings
- Switch Settings
- SNMP settings
- Spectrum Analyzer
- Antenna Alignment Tool
- Maintenance
- Instant DFS
- Troubleshooting
- Glossary
Infinet Wireless: Technical Documentation – Quanta 5 / Quanta 6
Installation– 55
•
•
•
•
•
•
•
•
•
6.4.2.2 AUX-ODU-LPU-LCable Ggland Assembly
In order to ensure that the cable gland remains sealed under any environmental conditions, please, follow the
assembly sequence according to the procedure below:
Step 1: Insert the sealing insert into the clamping claw.
Step 2: Assemble the cable gland by putting the thread-lock sealing nut, clamping claw with sealing insert
and body onto the cable as shown on the figure.
Step 3: Insert the clamping claw with sealing insert into the body as shown on the figure.
Step 4: Crimp the standard RJ-45 connector onto the cable using crimping tool.Pin-out scheme: T568B
wiring standards.
Step 5: Insert the RJ-45 connector into the correspondingsocket until you hear a click.
Step 6: Screw the cable gland body into the port and tighten it.Do not apply excessive force.
Step 7: Tighten thethread-lock sealing nut.Do not apply excessive force.
16 Figure - Cable gland assembly
6.4.3 Requirements to the lightning protection unit AUX-ODU-LPU-G location
AUX-ODU-LPU-Gis an optional accessory which may be used to serve as a line protection unit for theODUand for
the indoor network equipment connected to the Ethernet port of theIDU.
AUX-ODU-LPU-Gshould be properly assembled, mounted and grounded.
General recommendations for installations of lightning protection units:
Install the lightning protection unit on both ends of the cable to protect both the outdoor and the indoor
unit.The purpose of theLPUat the top is to protect theODUfrom a surge of lightning strike which can hit
the long FTP cablerun along the height of the pole or on the roof of the building.The purpose of theLPUat
the bottom is to protect theIDUand customer equipment.
Use the lightning protection unit to protect all circuits for signal transmission and power supply (video,
audio, management signals, Ethernet, etc.)
CAUTION
Make sure that the RJ-45 connector is well-crimped. A loose connector can damage the device. Please note
that such damage is not covered by the warranty.