«New task» window.
8. Restart the device.
After device restart “ERConsole” utility will reset device configuration to the
default.
9. Now login the device with any non-zero length login and password.
10. Reconfigure device username and password.
The “ERConsole” utility’s “New task” window also allows setting the units’ IP-
address on its Ethernet interface (eth0) without login to the unit. To perform this
procedure please follow the below steps:
1. Firstly, do steps 1-3 as described above.
2. Press «+» button in the «Scheduled tasks» section of the main window.
3. In the opened “New task” window choose “Up interface” in the “Command”
field. Then type the required IP-address and network mask in the corresponding
fields of the window and press “Ok” button.
4. Restart the device.
After the restart the “ERConsole” utility will add the IP-address into its Ethernet
interface configuration and will up the interface (in case it was configured
“down”).