User's Manual
Table Of Contents
- Table of contents
- I. Getting Started
- II. Hardware description
- III. Installation procedure
- 1. Installation preparations
- 2. InfiNet Wireless R5000-Omx/Omxb
- 3. InfiNet Wireless R5000-Lmn
- 4. InfiNet Wireless R5000-M/Mm and R5000-Smn/Smnb/Smnc
- 5. Mounting kit (MOUNT-KIT-85)
- 8. InfiNet Wireless R5000-Smnc
- II. Configuration (Web-interface)
- III. Configuration (CLI)
- IV. Link setup
- V. Lost password recovery
- VI. Recommendations
- VII. Supplementary information
37
Copyright © 2004-2012 by InfiNet Wireless
Step 1. Insert the sealing bush (6) into the cable gland case
(7) as shown on the picture.
Step 2. Assemble the cable gland as
shown on the picture by
placing the cable gland nut (8) on the cable gland case (7).
Put the cable sealing nut (5) and the cable gland assembly
(7,8) onto the cable as shown on the picture. Crimp the
regular RJ-45 connector (1) onto the cable using the cr
imping
tool. Do not use the shielded RJ-
45 connector (3) on this
end of the cable as it should be attached on the IDU end.
Make sure that the RJ-45 connector is well-
crimped. A
loose connector can damage the device. Please note
that such damage is not covered by the warranty.
Step 3. Attach the cable gland assembly to the device
socket.