Stop frequency, determining the ending frequency for scanning in MHz
Band - bandwidth in MHz
Step scanning frequency step in MHz
It is recommended to set 1 MHz “step” value to get more
precise scanning results.
Channel mask specifies which antenna will scan the radio environment.
“Auto” value set scanning by both antennas. This parameter is applicable
only to “R5000-Xm” models
Scan Duration time period for scanning in seconds. After the end of
this time period scanning will be stopped and radio interface will be back
to normal mode operation
Enable Grid draws grid lines and highlights the special frequency
channel on the scan output. Special highlighted frequency channel can
be used to mark a channel that the device is currently working on or that
is planned for using
Grid Width bandwidth value for the highlighted frequency channel in
MHz
Grid Frequency central operating frequency for the highlighted
frequency channel
Gradient Max RSSI shows gradient-color marked “Max RSSI” values on
the Spectrum Analyzer output screen.
To start/stop «Spectrum Analyzer» use «Start Sensor Test»/«Stop Sensor Test»
buttons.
Last Snapshot” button outputs the final scanning results. It is used when doing
a spectrum scan at the remote unit on the other side of the radio link. When
running a spectrum scan at such a unit (accessible via the RF interface),
connection to this unit will be lost for a scan time. "Last Snapshot" button allows
viewing scan results after the connection is up again.
Help” button displays the help note for the Spectrum Analyzer.
You can get detailed information about scanned radio signals on a specific
frequency. Just point a cursor on the needed frequency and you will see a hint
with exact Signal level (dBm), Frequency (MHz), Noise Floor (dBm), RSSI (dBm),
High RSSI (dBm), Max RSSI (dBm) values.