TM CORONA DISCHARGE OZONE GENERATORS CD-7 THRU CD-15 Main Power Ozone Power Vacuum High Coolant Temperature High Transformer Temperature Water Backflow Detector INSTALLATION & OPERATIONS MANUAL DEL INDUSTRIES, INC.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator TABLE OF CONTENTS SECTION 1 SECTION 4 General Information Maintenance & Service 1A. Description ........................................................... 1 1B. Specifications ...................................................... 1 1C. Warranty Summary............................................... 1 4A. System Electro-Mechanical Overview ................. 4 4B. PM Schedule ....................................................... 4 4C.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator 1C. Warranty Summary SECTION 1 Limited Warranty: 2 years on entire generator In addition to the two (2) year warranty: 3 years on weldments 5 years on high voltage electrodes 2 years on compressors that are maintained according to operation and maintenance manual. General Information 1A.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator 2B. Mounting 2B-1. Wall Mount Option 1. Attach two mounting brackets to wall using anchors appropriate for mounting surface. See figure 1. 2. Using 1/4"-20 bolts (with washers as shown) secure generator to mounts. 2B-2. Floor Mount Option 1. Use the 4 1/4"-20 bolts with washers to secure feet to bottom of cabinet. 2. Stand upright and securely fasten to concrete slab using appropriate anchors and bolts. 2C.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator Both (2) green indicator lights should be lit. If the optional ORP Controller is installed, it should be displaying a reading from the sensor probe and will automatically cycle the generator on and off as needed to maintain water quality. A high ORP (650-750 mV) is necessary for biological control. However, the system will not start under any of the following conditions: 1.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator SECTION 4 4A-3. Internal Components 1. Corona Discharge (CD) Module: Generator module consists of stainless steel water jacket and ground tubes and two end housings. Enclosed inside the module are the high voltage glass tube electrodes. The top end housing (the cylindrical glass chamber) encloses the high voltage connection for the electrodes and allows for visual inspection. 2.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator Figure 4: Component Locations 8. Gently glide glass tube electrodes out from module. Inspect for damage. 9. Wipe down electrodes using a solvent such as denatured alcohol and set in a safe area. 10. Swab out the stainless steel tubes using a solvent such as denatured alcohol or acetone. 11. Replace electrodes - be sure to wipe off any fingerprints, and reassemble module in reverse order. 2. Remove and clean air filter.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator 2. G.F.C.I. has tripped.* a. Check power cord and reset G.F.C.I. 3. Circuit breaker has tripped.* a. Reset breaker. *If G.F.C.I. or breaker continue to trip after reset, call for technical assistance. 2. Excessive ambient temperatures in installation area. a. Generator should not be exposed to ambient temperatures above 100°F. Higher temperatures may damage generator components. Symptom: “Water backflow detected” indicator light is on. 1.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator DEL INDUSTRIES, INC. LIMITED WARRANTY The limited warranty set forth below applies to products manufactured by DEL INDUSTRIES, Inc. - 3428 Bullock Lane, San Luis Obispo, California 93401, and sold by DEL INDUSTRIES and its authorized dealers. This limited warranty is given only to the first retail purchaser of such products and is not transferable to any subsequent owners or purchasers of such products.
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator APPENDIX “A” SAFETY 8
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator HEALTH HAZARDS OF OZONE FIRST AID Detection Levels General Ozone can be detected in air by its distinctive odor at concentrations of about 0.02 ppm. Although each nose varies, olfactory fatigue occurs quickly. As a result, DO NOT RELY ON ODOR AS A WARNING OF HIGH OZONE CONCENTRATIONS. First Action 1. If exposure to ozone causes headache or shortness of breath, immediately remove the patient to a fresh air environment. Second Action 1.