TUBE TL35 SE User Manual TL35 SE InfiRay Technologies Co., Ltd.
Contents Specifications ............................................................................................................................ 1 I. Package Contents............................................................................................................... 2 II. Introduction ....................................................................................................................... 2 III. Features ......................................................................
Specifications Model TL35 SE Detector Parameters Type Resolution Uncooled Vox 384x288 Pixel Size, μm 12 NETD, mk ≤40 Frame Rate, Hz 50 Optical Characteristics Objective Lens, mm Field of View, º 35 7.5 x 5.6 Visual Magnification, × 3.0-9.0 Digital Zoom, × 1.0~ 3.0 Eye Relief, mm 50 Diopter Adjustment, D Detection Range, m (Target Size: 1.7m×0.5m, P(n)=99%) -4~+4 1816 Display Parameters Type Resolution OLED 1536×1080 Power Supply Battery Max. Operating Time (at temp.
You can download this User Manual at our official website: www.infirayoutdoor.com. I. Package Contents TUBE TL35 SE Thermal Imaging Scope Eyeshade Picatinny rail clamp Portable bag Type-C cable Power adapter (for multiple countries) Lens cloth Heated target for zeroing II. Introduction TUBE TL35 SE is an infrared scope for outdoor hunting.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 50Hz frame rate; Internal memory space, supporting photo taking and video recording; Built-in Wi-Fi module, supporting app connection; Built-in compass and motion sensor; Optional laser rangefinding function, with a measuring range up to 1,000m; PIP (picture-in-picture) function; Pixel defect correction; Convenient operation interface. IV. Components and Controls 1. Eyeshade 2. Eyepiece diopter adjustment ring 3.
the device Wake up the Standby mode —— —— —— —— —— —— —— —— device Single ranging on under Perform the Home screen ranging operation Return Main menu interface single to previous the menu without saving Defective pixel calibration interface Add/delete defective pixels Adjust the image magnification Zoom (clockwise: zoom Home screen —— —— handwheel in; counterclockwise: zoom out) Press and hold for 2s: activate/deactivate the laser distance Switch between measurement Power Hom
11th Guiyang Street, YEDA, Yantai 264006, P.R.
When charging, a lightning charging icon appears on the battery icon, and the LED indicator (11) on the device is red. When the LED indicator (11) turns green, it indicates that the charging is completed; During use, if the battery icon turns red, it indicates that the battery level is low. Please charge the battery in time to avoid reducing the service life of the device due to the over discharge of the battery.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 VII. Mounting and Usage Fixed mounting WARNING: The lens of the thermal imaging scope must not be pointed at any sources of intense radiation energy, such as laser-emitting devices or the sun. This may damage the electronic components in the device. Damage caused by failure to comply with the operating manual is not covered under warranty. To ensure aiming accuracy, please fix TUBE TL35 SE at a proper position on the weapon.
to enter the home screen to complete the startup.
th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 VIII. Status Bar The status bar is located at the top of the image interface, as shown in Figure n, and displays the information related to the current operating status of the device. From left to right, there are: 1. Current image mode ( : white hot; : black hot; : red hot; : palette; : highlight) 2. Current zeroing profile and zeroing distance (e.g., A100m); 3.
sufficient. When it is orange , the charge is between 10% and 20% and the device needs to be charged in time. When it is red , the charge is less than 10% and the device needs to be charged in time. When a lightning sign appears in the battery icon, the built-in battery is being charged. IX. Digital Zoom The TUBE TL35 SE scope supports the 3.0–9.0 zoom function, by which you can magnify an image by 1 to 3 times.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 The images taken are saved in the internal storage space in the format of "PIC_HHMMSS", with HH indicating hours, MM indicating minutes, and SS indicating seconds. Video Recording On the home screen, press and hold the controller (4) for 1.
Connect the device to a computer through the USB cable; Power on the device; Double-click My Computer, double-click to open the device named Infiray , and then double-click to open the device name TUBE SE Storage to access the memory; Folders named by date are displayed. The naming format is “YYYYMMDD” (8 digits), with YYYY indicating year, MM indicating month, and DD indicating date; The folders store the videos/images captured on the corresponding days.
11th Guiyang Street, YEDA, Yantai 264006, P.R.
- Reticle Style: Turn the controller (4) to select the reticle style, and press the controller (4) to switch between 6 styles; - Reticle Color: Turn the controller (4) to select the option, and press the controller (4) to adjust the colors, including black, white, red, and green; - Image Sharpness: Turn the controller (4) to select the option, and press the controller (4) to adjust the image sharpness from levels 1 to 5; - Zeroing Distance: Turn the controller (4) to select the option, and press the control
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 white into blue; The operations for secondary and tertiary menus are the same as above; On any menu screen, press and hold the controller (4) to save the changes and return to the home screen.
handwheel (3), the image shown in the PIP window will also be magnified by 2×.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 Enabling/Disabling Compass Press and hold the controller (4) to open the main menu; Compass Turn the controller (4) to select Digital Compass; Press the controller (4) to enable/disable Digital Compass; When Digital Compass is enabled, its icon is displayed in the middle of the status bar on the top.
Press the controller (4) to enable/disable Bluetooth; Bluetooth has three states: Icon: Bluetooth is disabled; Icon: Bluetooth is enabled but not connected to the rangefinding module; Icon: Bluetooth is enabled and connected to the rangefinding module. In this case, you can perform laser rangefinding operations by using the combination key of the rangefinding function (for details, refer to Chapter XI Laser Rangefinding).
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 Turn the controller (4) to select the zeroing distance according to the distance set for the target; Press the controller (4) to confirm the zeroing distance, and open the zeroing distance submenu, including two options, that is Zeroing and Zeroing Distance.
point of impact. After zeroing, press and hold the controller (4) to save the zeroing result. At this time, the countdown message "saving... 5” and the “saved successfully” prompt are displayed.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 zeroing distance; After the zeroing distance is saved, enter the zeroing function for zeroing (for details, refer to Zeroing Settings > Zeroing Function in Chapter XIII. Main Menu). After zeroing, press and hold the controller (4) to save the zeroing results. In the saving process, the 5s countdown message "data saving... 5” is displayed. After successful saving, the “saved successfully” prompt is displayed.
standby mode is disabled.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 downward; turn the controller (4) counterclockwise to move the indication box upward; -Center: Press the power button (5) to center the indication box on the screen. Figure n. Laser Calibration When using the scope, you may see pixel defects, such as visible light spots or dark spots with stable brightness. To address this problem, use the Pixel Defect Correction function to remove the pixel defects.
button (5) to add and correct it. When Add is displayed in the PIP window, it indicates that the pixel defect has been added, and the number of corrected defective pixels is increased by one. This process can be repeated for correcting other pixel defects; At the position of the same defective pixel, press the power button (5) again to cancel the correction at this position.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 Calibrating Compass Turn the controller (4) to select Compass Calibration from the main menu; Press the controller to open the Compass Calibration interface. The calibration icon is displayed; Rotate the scope along the three axes indicated by the icon, with each axis Compass rotating at least 360°; Calibration The calibration ends after 15s by default and the interface closes automatically.
Press the controller (4) to activate the date reset function, with the date in the format of YY/MM/DD; Press the controller (4) to switch between year, month, and date; Turn the controller (4) to set the correct year, month, and date; After setting, press and hold the controller (4) to save changes and exit the date reset function. Setting System Time Press the controller (4) to open the secondary menu of Settings; Press the controller (4) to select Time.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 Selecting Language Press the controller (4) to open the secondary menu of Settings; Select Language, and press the controller (4) to open the secondary menu of Language; Turn the controller (4) to switch between English, Russian, and German; Language Press the controller (4) to confirm and save the selection, and return to the menu interface.
and exit the interface. Enabling/Disabling Status Auto Hiding Press the controller (4) to open the secondary menu of Settings; Select Status Auto Hiding, and press the controller (4) to open the secondary menu of Status Auto Hiding; Status Auto Hiding Turn the controller (4) to select Hide or Show; Press the controller (4) to confirm the selection, and return to the main menu.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 If Yes is selected, the scope re-start automatically; If No is selected, the operation is canceled and the upper menu is displayed.
XIV. Calibration When the image is degraded or uneven, it can be improved by calibration. Calibration can balance the background temperature of the detector and eliminate the defects in the image. There are three calibration modes: Automatic (A), Manual (M), and Background (B). Select the required mode from Calibration on the main menu.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 When using the scope for the first time, press and hold the controller (4) and power button (5) for more than 8s to enable the hidden reticle and zeroing functions; Select a target at a certain distance, such as 100m and 200m; Adjust the scope according to the operating instructions as described in Power-on and Settings in Chapter VII; Select the zeroing profile (refer to Zeroing Profile in Chapter XIII.
After moving the reticle, a little white dot appears on the screen, indicating the position of the reticle before moving; After moving the reticle position to the actual point of impact, press and hold the controller (4) to save the current reticle position and return to the home screen; Repeat aiming and shooting, until the position of the point of impact is consistent with that of the aiming point.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 XVII. Wi-Fi TUBE TL35 SE has a built-in Wi-Fi module and can connect wirelessly to a mobile device (laptop or mobile phone) via Wi-Fi. On the main menu, enable Wi-Fi. For detailed operations, refer to Wi-Fi in Chapter XIII.
in real time, operate the device, and update device software by connecting the device to a mobile phone or laptop via Wi-Fi. You can download the user manual of InfiRay Outdoor at our official website (www.infirayoutdoor.com). You can also test and update the software of the product via the InfiRay Outdoor app or download it on our official website. About InfiRay Outdoor You can download and install the InfiRay Outdoor app on our official website (www.infirayoutdoor.com) or the app store.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 XIX. Technical Inspection Perform a technical inspection to check the following items each time before you use the device. Exterior of the device (no crack on the enclosure); Lens and eyepiece (no crack, oil, stain, or other sediments); Status of the rechargeable battery (fully charged in advance) and electrical contact (no salinization or oxidation). XX.
started. The device cannot be The USB cable is damaged. Replace the USB cable. powered by using an The external power supply is If necessary, check the external power external power supply. insufficient. supply. Images vertical are unclear, lines are Calibrate the images as instructed in Calibration is required. present, or the Chapter XIV of the User Manual. background is not even. The screen is not bright The image is too dark. Adjust the display brightness enough.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 necessary, wipe off any dust and frost on it. In cold weather, a special antifogging coating can be applied (such as those used on eyeglasses or car rearview mirrors). The Wi-Fi password is Enter the correct password. incorrect. The device cannot To enable stable network access, you There are too many Wi-Fi connect to a mobile are advised to move the device to an networks in the range of the phone or computer.
Therefore, the image quality (details in particular) is poor, which is a characteristic of thermal imaging devices. FCC Caution §15.19 Labelling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. §15.21 Information to user.
11th Guiyang Street, YEDA, Yantai 264006, P.R. China +86-400-998-3088 Body Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 0 mm must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components.