InfiRay Outdoor • Tube TD50L • Operating Manual Operating Manual Tube Serise TD50L V1.
IMPORTANT SAFETY INFORMATION Environmental influences WARNING! Never point the lens of the device directly at intense heat sources such as the sun or laser equipment. The objective lens and eyepiece can function as a burning glass and damage the interior components. The warranty does not cover damage caused by improper operation. Risk of swallowing Caution: Do not place this device in the hands of small children. Incorrect handling can cause small parts to come loose which may be swallowed.
defective, send the device to our after-sales service for when you purchase a corresponding new product. The repair. proper disposal of this product serves to protect the environment and prevents possible harmful effects on Safety instructions for the power supply unit - Check the power supply unit, cable and adapter for visible damage before use. - Do not use any defective parts. Defective components - must be replaced. - Do not use the power supply unit in wet or humid environments.
Function test SPECIFICATIONS - Model Before use, please ensure that your device has no visible damage. - Test to see if the device displays a clear, undisturbed image. - Check that the settings for the scope are correct. See the notes in the section Operation. TD50L Detector Specifications Sensor Resolution, pixels 1440 × 1080 Frame Rate, Hz 50 Optical Specifications Objective Lens, mm 50 / F1.2 Field of View, º 6.6 × 4.9 Installing/removing the battery Optical Magnification, × 4.0 ~ 16.
Model TD50L Dimension, mm 395 × 85 × 75 APP / Wi-Fi Support (InfiRay outdoor) Stadiametric Rangefinder IR Illuminator**, nm Support 850 / 940 (Optional) Max Power of IR Illuminator, w * 2.2 Actual operation time depends on the density of Wi-Fi use and video recording functions. ** The product package does not contain the IR illuminator. Please select 850nm/940nm IR illuminator according to your own needs.
COMPONENTS AND CONTROLS BUTTON DESCRIPTION Button Power Button Current Status Press Powered off —— Power on the device —— Home screen Standby Shut down the device —— Standby Wake up the device —— —— —— —— Turn on/off the PIP function —— Return to the upper Main menu menu screen without saving changes Palette button Brightness button 1. Eyeshade 8. USB cover 2. Eyepiece adjusting ring 9. Type-C port 3. Camera button 10. LED indicator 4. Brightness button 11.
Button Current Status Press Press and Hold Confirm the option Main menu parameters Save and interface / Open back to the the main submenu menu Zeroing interface Switch between the X axis / Y axis Rotate Move reticle position: Clockwise: move to the left / down direction; Anticlockwise: move to the right / up direction POWER SUPPLY The Tube series adopts a dual power system (built-in chargeable Lithium-ion battery pack and a replaceable 18500 battery).
Installing 18500 battery If there is no replaceable battery in the device, only the green icon of the built-in battery is displayed on the right. If the both batteries are fully charged, the replaceable battery will be preferred to power the device. If the replaceable battery level is low, the device will switch to the built-in battery automatically. When connecting to the external power supply using the USB port (9), it will switch to the external power supply automatically.
0°C to +40°C. Otherwise, the battery life will be device switches to the replaceable 18500 battery for significantly reduced. power supply. If no replaceable 18500 battery is installed When charging, please do not leave the battery or the battery level is low, it will switch to the built-in unattended. battery pack, instead of shutdown. Do not connect the battery to the power supply for more than 24 hours after it is already fully charged.
2.5nm. Setting the image sharpness: Press the rotary Before using the scope for hunting, please zero the encoder (7) to enter the shortcut menu, and set the device first according to the instructions as specified in the Zeroing section in this manual. It is recommended to use an eyeshade while using the scope in the dark in order to avoid detection of camouflage. Mounting the eyeshade on the eyepiece is carried out through the thread. image sharpness (refer to the section Shortcut Menu for details).
right is the position of the point of impact (This mark is ZEROING The Tube series adopts the “freezing” zeroing method. It only for illustration. It should actually be a bullet hole). is recommended to perform zeroing in environments within the operating temperature range of the scope. Fix the scope with the mount clamp on your weapon. For details, refer to the section Installation. Select a target at a certain distance, such as 100m, 200m, etc.
point of impact is consistent with that of the aiming point. Note - After the zeroing position is set up, you can switch the options of Zeroing Distance in the shortcut menu. DIGITAL ZOOM The Tube series Scope supports the Infinite zoom function of 4.0 - 12.0, by which you can magnify an image by 1 to 4 times. On the home screen, turn the rotary encoder (7) to zoom in/out the image. Zoom in by rotating clockwise, and zoom out by rotating anticlockwise.
Double click "My Computer" on the desktop of your Note - The menu can still be operated during video recording. - The images and the videos are stored in the built-in memory card in the format of IMG_HHMMSS_XXX.jpg (for images) and VID_HHMMSS.mp4 (for videos). HHMMSS - hours/minutes/seconds, XXX - three-digit common counter for photos which is NOT reset. - If a file is deleted from the list, its number is not taken by the other file. - The maximum duration of a video recording file is 10 minutes.
Colored battery icon indicates that the battery is - battery life. Icon - Color/Status Battery Status Green more than 40% Yellow 20% - 40% Less than 20%, need to charge instantly Red Lightning icon inside External power supply meanwhile charging the built-in battery pack Reticle Style : Rotate the rotary encoder (7) to select the reticle style, and press the rotary supplying power. The levels of it show the remaining encoder (7) to switch among 6 styles.
The operation of secondary and tertiary menus is the same as above. In any menu interface, press and hold the rotary encoder (7) to save the changes and return to the upper menu interface. And, briefly press the power button (5) to return to the upper menu without saving. In the main menu interface, the device will automatically return to the home screen without any saving if there is no operation within 15s.
Press the rotary encoder (7) to confirm the selection, and return to the main menu. The name of the selected profile will change in the status bar. directly as follows. Select the Zeroing option and briefly press the rotary encoder (7) to enter the Zeroing interface. The X axis and Y axis coordinates of the reticle are displayed at the top left corner of the screen.
Press the rotary encoder (7) to activate the displayed on the top status bar. zeroing distance reset function, and then two small triangle symbols are displayed above and below the number . Rotate the rotary encoder (7) to set the number value of the current position from 0 to 9. If off is selected, the standby function is disabled. Note - standby mode is activated automatically: up > 70° or Press the rotary encoder (7) to switch among the positions of hundred, ten and one digits.
icons appearing above and below the value. Date format is displayed as YY.MM.DD format. Rotate the rotary encoder (7) to set the correct year, month and date. Press the rotary encoder (7) to switch among year, month and date. After setting, press Language-Selecting language In the Settings submenu, rotate the rotary encoder (7) to select the Language option. Press the rotary encoder (7) to enter the submenu for language selection. Rotate the rotary encoder (7) to switch among English and Russian.
- Optical Magnification: 4.0× option. Press the rotary encoder (7) to enter the submenu - Standby: Off - Wi-Fi: Off of the status auto hiding option. Rotate the rotary encoder (7) to select On or Off. - Language: English - Unit of Measure: Meter Press the rotary encoder (7) to - Status Auto Hiding: Off confirm the selection Info-Show device information and return to the upper menu interface. ● In the Settings submenu, rotate the rotary encoder (7) to select the Factory Reset option.
on the top of the display simultaneously with the main image. ● ● side. ● Three pre-defined target values are provided as When the main image is enlarged by rotating the follows: encoder (7), the image shown in the PIP window is - Deer: 1.7m high also enlarged accordingly. - Wild boar: 0.7m high For example, when the - Hare: 0.2m high magnification of the main ● image is 4×, the corresponding Adjust the device to locate the target in the center of the display area.
● Press the rotary encoder (7) to enter the submenu of Status Auto Hiding option and then select On or Off by rotating the rotary encoder (7). ● After the status auto hiding is enabled, all GUI icons ● The Wi-Fi name and password of Tube series can be reset in the InfiRay Outdoor application.
application. Also, it is feasible to download and update software from the official website: www.infirayoutdoor.com. It is recommended to carry out a technical inspection each time before using the scope. Check the following: About InfiRay Outdoor ● TECHNICAL INSPECTION You can get InfiRay Outdoor application in the official website (www.infirayoutdoor.com), or search InfiRay ● the body).
TROUBLESHOOTING Faults Possible Causes The scope or the mount clamp is not fixed firmly. Configuration error Set the scope according to the section Operation. Check the outer surface of the objective lens and eyepiece, and if necessary, wipe off any dust and frost on it. In cold weather, a special antifogging coating can be applied (such as those used on eyeglasses or car rearview mirrors).
LEGAL AND REGULATORY INFORMATION Note: The manufacturer is not responsible for any radio or Wireless transmitter module frequency range: authority to operate the equipment. WLAN: 2.412-2.472GHz (For EU) Wireless transmitter module power<20dBm (only for EU) IRay Technology Co., Ltd. thus declares that the Tube series digital night vision scope complies with the directives 2014/53/EU and 2011/65/EU. The full text of the EU declaration of conformity as well as additional information are available at: www.
operations. To comply with RF exposure requirements, a minimum separation distance of 0cm must be maintained between the user's body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna. We, IRay Technology Co., Ltd.