Operation Manual

IN134UST/IN136UST Manual del usuario
57
No Función Comando
RW
(L/E)
Mín. Máx.
Por
defecto
Paso Parámetro
16 Color Temp TMP RW 0 3
Source
Specific
1
Display Mode=User only
0:Native
1:Warm
2:Normal
3:Cold
17 Contrast CON RW 0 100 50 1 Display Mode=User only
18 Current Source SRC RW 0 4 0 1
0:VGA1
1:VGA2
5:HDMI
12:Composite
13:S-Video
21 Digital Zoom DZM RW -10 10 0 5 -10~10
27 Error Condition ERR R n/a n/a n/a n/a
0:No error
1:Lamp not lit after 5 At-
tempts
3:Lamp went out unexpect-
edly
4:Fan failure
5:Overheating
8:DMD error
9:Color wheel
28 Factory Reset RST W n/a 1 1 1 1:Reset
32 Freeze Screen FRZ RW 0 1 0 1 0: Disable
34 Gamma GTB RW 0 4
Source
Specific
1
Display Mode=User only
0:PC
1:MAC
2:Video
3:Chart
4:B&W
40 Horz. Position HPS RW x x 0 1
RGB source only
(HPS?) to get range
45
Lamp Hours in High
Power (Normal) Mode
LMO R 0 9999
Displays the numbers of
hours that the lamp has run
in High Power (Normal)
mode.
46
Lamp Hours in Low
Power (Eco) Mode
LME R 0 9999
Displays the numbers of
hours that the lamp has run
in Low Power (Eco) mode.
47 Lamp Life LIF R n/a 5000 230W lamp life 5000
49
Lamp Resets (Total
number)
LMR R 0 9999 0 1
62 Lamp Low Power IPM RW 0 1 0 1 1=Normal, 0=Bright