Regulatory Standards Compliance
GSM compliance
Reference regulations: TBR 19, TBR 20, TBR 31, TBR 32.
Table B-1: ModemModule Acceptance Test
Tests Applied Standard Acceptance Criteria
Performance
Test
ETSI recommendation
for GSM/DCS
communication
Full conformity to the recommendation regarding the
main RF parameters.
Cooking Test The test continues even after the Cooking Test
milestone has been reached.
Stress Test Thermal shocks,
IEC 68-2-14.
Full conformity to the recommendation regarding the
main parameters.
Vibration Test Sinusoidal vibration,
IEC 68-2-6.
No performance degradation or mechanical
degradation is allowed after test.
Vibration Test Random vibration,
IEC 68-2-36.
No performance degradation or mechanical
degradation is allowed after test.
Shock Test IEC 68-2-27. No performance degradation or mechanical
degradation is allowed after test.
Bump Test IEC 68-2-29. No performance degradation or mechanical
degradation is allowed after test.
Humidity Test Corrosion test,
IEC68-2-3.
No visible degradation of the product, both visual and
functional.
The unit is tested at room temperature and must be
fully operative for the main RF parameters.
Warehouse
Test
Low temperature
IEC 68-2-1.
Under normal conditions (room temperature) after the
test, the unit must behave in full conformity with the
main RF parameters.
Warehouse
Test
High temperature
IEC 68-2-2.
Under normal conditions (room temperature) after the
test, the unit must behave in full conformity with the
main RF parameters.
Dust Test MIL-STD-810D,
method 510-3.
No visible dust in the visible areas. No more than 50
dust particles in the cabinet of the product. The unit,
tested at room temperature, must be fully operative.
Light Test UV radiation and
temperature EDF
HN60E03.
Visual inspection on the discoloration and other
degradation effects such as cracks I the material of
the unit after test.
Fall Test IEC 68-2-32. Only minor casing degradation is allowed, with a
maximum dimension change of 1mm. The unit must
remain fully operative and fully meet specifications for
the main RF parameters.
Electro Static
Discharge
Test
IEC 100-4-2. No performance degradation allowed after the test.
Salt Mist
Test
IEC 68-2-11. After the test, visual inspection on the unit.
Atmosphere
Test
Flowing mixed gas
corrosion. IEC 68-2-60.
After the test, visual inspection on the unit and inside.
Marking Test EN 60 950 After the test, visual inspection on the unit. No
degradation is allowed on the marking.