User Guide Model:AXIUM EX6000 WWW.ingenico.
Contents 1. Introduction ..................................................................................................................... 3 2. Presentation ..................................................................................................................... 4 2.1 Content of the box .................................................................................................... 4 2.2 Overview of AXIUM EX6000.......................................................................
1. Introduction We hope that you will be fully satisfied with your new AXIUM EX6000 terminal. Read thisguide to understand and make the best use of your terminal. It presents you the necessary information about use,installation,maintenance,safety and security recommendations. WARRANTY/SECURITY/GARANTIE/SÉCURITÉ Use only the power supply included with the product to ensure best performance and safety.Maintenance should only be provided by Ingenico authorized technician.
2. Presentation 2.1 Content of the box AXIUM EX6000 terminal Power adapter Abattery pack This user guide WARNING/ATTENTION The power supply unit provided with your equipment is specially designed for ingenicoAXIUM EX6000 terminal. Do not use any other power supply.The use of a power supply with apparently similar voltage/current characteristics may damage your terminal. Le bloc d’alimentation fournit avec votre équipement est spécialement conçu pour les terminaux de paiment Ingenico.
2.2 Overview of AXIUM EX6000 1. Volume Keys 2. Scan Key 3. LCD and touch screen 4.USB Type-C connector 5.Smart card reader 6. Indicate LED of front scanner 7. Front scanner 8. Illuminate lamp of front scanner 9.Magnetic card reader 10.Contactless landing zone 11.Power Key 12.
13. LEDs for Contactless Card 15. SAM card slot16. Micro SD slot 17. Battery socket18. Base Charging interface19. Flash20. Rear camera 21. SIM 1 card slot22.SIM 2 card slot 23.Battery compartment24.Lanyard hole 25. Base Charging interface+ Weight Dimension (L x W x H) Electrical mains network 2.3 Keypad Functions 6 / 25 14. Speaker 261g (including battery) 152.2 X 77.1 X 17.
The terminal has three physical keys on the left side of the terminal, a power button and two volume keys. The terminal has a 5.0 inchscreen,there are three capacitive keys at the bottom of the screen,Menu,Homeand Back keys. 2.4 Touch Panel The AXIUM EX6000 is equipped with touch panel that allows you capture functions and menus by your finger or use a stylus. 3. Use of the terminal 3.
button for about 1s until the display is turned up. To power off: Press button for more than 2s until the display show the following figure, then press . If the battery is empty, the terminal automatically shuts off. Abnormal power off: When the device works abnormally, for example, it is crashed and no actions menu popped out while pressing the power button, pleaselong-press the power button for 8s, the device will be automatically powered off.
The card can be read bi-directionally, with the stripe facing the terminal. Use a regular movement in order to ensure a reliable card reading. Contactless card Bring the card firmly up to the active zone. Keep the card close to the reader during the transaction. On the back ,LEDs are displayed to indicate transaction processing. Smart card Insert the card horizontally with the metal chip facing upward and leave in position throughout the transaction. 3.
scanning. After starting the barcode scanning, a red laser beam will be emitted from the window in front of the terminal. Align the red light beam with the bar code you want to scan When the scan is successful, the terminal will automatically turn off the beam and sound a beep. 3.4USB type-C There is a USB type-C connector on the left side of terminal. The connector manages Host and Slave connections. The connector integrates Audio Jack solution. 4.
4.1 Recommendations Operating conditions Ambient temperature* Max relative humidity From -10℃ to +50℃ From 10%to 90%, Non-condensing (*)Excluding battery charging Battery charging conditions Ambient temperature From 0℃ to +40℃ Storage conditions Ambient temperature Max relative humidity From -20℃to +70℃ From 5% to 90%, Non-condensing 4.2 Installing modules 4.2.1 SAM/SIM1/SIM2 WARNING/ATTENTION Switch off the terminal before opening the trapdoor.
When introducing a SAM/SIM in its slot, be sure to put the cut corner as indicated on the picture. Close the trapdoor. ADVICE SIM and SAM cards share the same form factor , please do be careful to the SIM card socket position. 4.2.
Switch off the terminal before opening the trapdoor. Mettre hors tension le terminal avant d’ouvrir la trappe. MicroSD connector is located inside the terminal, in a closed compartment. Turn the terminal and remove the trapdoor. MicroSD are identified by the engraved marks on the lower housing. When introducing a MicroSD in its slot, be sure to put the cut corner as indicated on the picture. Close the trapdoor. The terminal supports MicroSD up to 32GB. 4.3Battery 4.3.
Place the battery pack in its compartment. Close the battery trapdoor. 4.4 Visual Impaired Accessory Install the VI accessory on the screen. Take out the VI accessory.
5. Recommendations 5.1 Safety Powering down the AXIUM EX6000 Disconnect the AXIUM EX6000 power supply block adapter from the electrical mainsnetwork. Lithium cell The AXIUM EX6000 is fitted with an internal lithium cell which should only be accessed by a qualified technician. Battery AXIUM EX6000 is fitted with battery specially designed for this terminal. Only use the appropriate chargers and batteries listed in theingenico’s catalogue. Do not short-circuit the battery.
RISK OF EXPLOSION BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. RISQUE D'EXPLOSION LA BATTERIE EST REMPLACÉE PAR UN TYPE INCORRECT. ÉLIMINEZ LES PILES UTILISÉES CONFORMÉMENT AUX INSTRUCTIONS. Electrical power supply network The electrical outlet must meet the following criteria: Must be installed near the equipment and easily accessible Do not short-circuit the battery. Do not attempt to open the battery container.
BSMI(Taiwan) PSE Mark(Japan) Recycle in accordance with the waste electronic & electrical equipment directive Underwriters Laboratories Inc (US Compliance) Made from recyclable material Low density version of Polyethylene (LDPE) Chlorinated Polyethylene ( CPE) Risk of explosion if the battery is incorrectly replaced or is placed in a fire Dispose of batteries at a hazardous waste collection site or recycling facility 17 / 25
Direct Current SAM/SIM1/SIM2Readers compartment The trapdoor for battery, SAM/SIM1/SIM2, readers located underneath the terminal, must be in place during the normal operation of the terminal.See sections “Installing modules” and “Installing the battery”. On airplanes Your terminal must be switched off by removing the battery pack. Remove the battery from the terminal when on an airplane.
Detected” and further use of the terminal will not be possible. If you observe the “Warning Detected” message, you should contact the terminal helpdesk immediately. You are strongly advised to ensure that privileged access to your terminal is only granted to staff that have been independently verified as being trustworthy.The terminal must never be put in or left at a location where it could be stolen or replaced by another device. 5.
5.4Cleaning the terminal Unplug all the wires from terminal. Good rules for proper cleaning of the terminal are: Use a soft cloth that is very slightly soaked with soapy water to clean the outside of terminal. Do not clean the electricalconnections. Do not use in any case, solvents, detergents or abrasive products: Those materials might damage the plastic or electrical contacts. Avoid exposing the terminal to the direct rays of the sun. Do not put anything into the slot of the smart card reader.
6. Standard FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
approved for the transmitter by Innovation, Science and Economic Development Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that, the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation ISEDC, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gainmaximal (ou inférieur) approuvé pour l'émetteur par Industry canada.
Packaging waste must also be collected separately to assure a proper disposal and recycling. In this way you can participate in the re-use and upgrading of Electrical and Electronic Equipment Waste, which can have an effect on the environment and human health. 7. Troubleshooting Q:The terminal cannot be started. A: The device might be under low energy status or the program may be damaged. Please make sure the power is enough and thenrestart your device.
This Document is Copyright © 2020 by ingenico Group. ingenico retains full copyright ownership, rights and protection in all material contained in this document. The recipient can receive this document on the condition that he will keep the document confidential and will not use its contents in any form or by any means, except as agreed beforehand, without the prior written permission of ingenico.
WWW.ingenico.com 28-32,Boulevard de Grenelle, 75015 PARIS - FRANCE/ (T)+33(0)1 58 01 80 00 / (F)+33 (0)1 58 01 91 35 Ingenico-SA au capital de 47 656 332 / 317 218 758 RCS Nanterre.