4. Click Browse, and navigate to the location of the ingest file.
5. Click Upload.
6. Click Save. The pop-up window asks the operator to confirm the configuration of the
Gateway.
7. Click Yes.
3.4.3 Restarting the Gateway
After uploading the ingest batch file, restart the Gateway.
To restart the Gateway, complete the following steps:
1. In the Devices pane, click Gateway.
2. Select the Gateway to restart, and click Restart Gateway. The pop-up window asks the
operator to confirm the restart.
3. Click Yes.
3.4.4 Configuring Access Points with the Ingest File
To configure access points with the ingest file, complete the following steps:
1. Log in to the EMS with an admin account.
2. Click the Devices tab.
3. Click Batch Upload.
4. To start the AP, reload the configuration file, upload, save, and confirm the upload.
5. To confirm the status of the AP, select Devices Access Point in the Devices pane.
NOTE:
The EMS AP status does not update immediately. Eventually, the status shows that
the AP has transitioned to a yellow state. Alternatively, the operator can click
Refresh from the Access Point Device Listing screen. Depending on when the screen
is refreshed, the operator will see Waiting for Time Sync or Waiting for RF Metrics
display in the State field. This is normal behavior for an AP that is transitioning from
an offline state to an online state. The AP goes through an initialization period in
which it first finds GPS and then measures the RF noise that the AP experiences.
During this process, the AP adjusts the RF behavior accordingly. Typically, this
adjustment takes approximately 2.5 minutes to complete.