8 7 6 5 4
3
2 1
8 7 6 5 123
D
C
B
A
D
C
A
B
4
COPYRIGHT @ 2018
Ingersoll Rand
ALL RIGHTS RESERVED
CAD GENERATED DRAWING,
NO MANUAL REVISIONS ALLOWED
DRAWING CONFORMS TO
ASME Y14.5M - 1994
DO NOT SCALE DRAWING
PROPRIETARY NOTICE
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS
GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET
INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.
WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS.
THIRD ANGLE PROJECTION
DWG NO.
PART NO.
ESTIMATED WEIGHT
(KG UNLESS OTHERWISE SPECIFIED)
A1
NAME
SIZE
MODEL
SHEET
REVISION
SCALE
R
GENERAL ARRANGEMENT
TOLERANCES
ALL DIMENSIONS ARE IN
MILLIMETERS
[INCHES (IF SHOWN)]
UNSPECIFIED TOLERANCES:
ANGLES
.X
WHOLE :
:
:
13.0[.50]
6.0[.25]
1
Ingersoll-Rand Industrial Technologies
REVISIONS
APP'DDRAWNDATEDESCRIPTIONECNREVZONE
Z.WHITLEY G.SRIKANTH2014MAY05 ORIGINAL RELEASE790486 A
Z.WHITLEY
M.PREETHAM
2014DEC15ADDED SHEET 9,
DIM 631.0 [24.84] WAS 634.7 [24.99],
DIM 266.7 [10.50] WAS 267.0 [10.51],
DIM 35.7 [1.40] WAS 19.5 [.77],
DIM 266.7 [10.50] WAS 295.0 [11.61],
DIM 665.9 [26.22] WAS 663.2 [26.11],
DIM 1161.2 [45.72] WAS 1178.1 [46.38],
DIM 1215.2 [47.84] WAS 1246.2 [49.06],
DIM 438.2 [17.25] WAS 456.0 [17.95],
DIM 285.8 [11.25] WAS 183.0 [7.20],
DIM 13.9 [.55] WAS 22.6 [.89],
DIM 158.8 [6.25] WAS 145.0 [5.71].
960610B
3-B3
3-B3
3-C3
3-C2
4-B6
4-B6
4-B6
4-B6
4-C6
4-C6
4-C5
Z.WHITLEYA.DHANA2015JUL17ADDED SHEET 10, DIM 401.0 [15.79] WAS 403.0[15.87]
DIM 289.0 [11.38] WAS 291.0[11.46]
DIM 34.8[1.37] WAS 35.7[1.40]
DIM 14.0[.55] WAS 13.9[.55]
DIM 158.7[6.25] WAS 158.8[6.25]
DIM 401.0 [15.79] WAS 403.0[15.87]
DIM 289.0 [11.38] WAS 291.0[11.46]
IN NOTE 5 ADDED RECOMMENDED CLEARANCE
FOR VSD PACKAGES.
974303C3-C7
3-B7
3-C3
4-C5
4-C5
6-C7
6-B7
1-C8
C.FRAZIER
M.PRASHANT
2018JAN31REC. TANK 24246035 WAS 24491540 (< 200 PSI)
REC. TANK 47618489001 WAS 47529410001 (> 200 PSI)
UPDATED DRAWING AS PER NEW RECEIVER TANKS
1285281D
GENERAL ARRANGEMENT,
R4-11KW 80G RECEIVER MOUNTED
GENERAL ARRANGEMENT, R4-11KW 80G RECEIVER MOUNTED
SEE NOTE 1
47518742001
47518742 001
D
0.15 R4 - 11KW 10 OF 1
For Internal Use:Model=47518742001|ASSEM|D.3|Dhananjaya A L|05-Feb-18 03:01:49 PM|Design<>Drawing=47518742001|DRAW|D.5|Dhananjaya A L|05-Feb-18 03:01:49 PM|Design
D.5
DRAWN DATE
G.SRIKANTH 2014MAY05
CHECKED DATE
Z.WHITLEY 2014MAY05
APPROVED DATE
Z.WHITLEY 2014MAY05
DRAWING TYPE
General Arrangement Drawing
NOMENCLATURE
NOTES:
1. WEIGHT (APPROXIMATE): R4I (80G RECEIVER) - 400kg
R4I (80G TAS) - 465kg
R5.5I (80G RECEIVER) - 400kg
R5.5I (80G TAS) - 465kg
R5.5N (80G RECEIVER) - 405kg
R5.5N (80G TAS) - 470kg
R7.5I (80G RECEIVER) - 400kg
R7.5I (80G TAS) - 465kg
R7.5N (80G RECEIVER) - 405kg
R7.5N (80G TAS) - 470kg
R11I (80G RECEIVER) - 415kg
R11I (80G TAS) - 485kg
R11N (80G RECEIVER) - 425kg
R11N (80G TAS) - 495kg
2. COOLING AIR FLOW: 1950m3/h
3. PIPE CONDENSATE DRAIN LINES SEPARATELY TO AN OPEN
DRAIN DUE TO DIFFERENCES IN DRAIN PRESSURES. READ
OPERATIONS MANUAL AND CHECK LOCAL REGULATIONS.
4. LUBRICANT FILL QUANTITY: 5 LITERS.
5. RECOMMENDED CLEARANCE ON THREE SIDES 915MM (36 INCHES),
ON SIDE WITH ELECTRICAL BOX OPENING 1067MM (42 INCHES) OR
MINIMUM AS REQUIRED BY LATEST NATIONAL ELECTRICAL CODE OR
APPLICABLE LOCAL CODES.
FOR VSD PACKAGES ONLY: ENSURE THAT A MINIMUM CLEARANCE OF
102 MM (4 INCHES) IS MAINTAINED IN FRONT OF THE PDM FILTER TO
ALLOW ADEQUATE SPACE FOR MAINTENANCE.
6. EXTERNAL PIPING SHOULD NOT EXERT ANY UNRESOLVED MOMENTS
OR FORCES ON UNIT. USE PIPE OF EQUAL OR GREATER SIZE AT DISCHARGE
LOCATION OF UNIT.
7. THERE SHOULD BE NO PLASTIC OR PVC PIPING ATTACHED TO THIS
UNIT OR USED FOR ANY LINES DOWNSTREAM.
8. REMOVE THE ISOLATION MOUNT RESTRAINTS BEFORE THE INITIAL START.
THE RESTRAINTS CAN BE DISCARDED.
9. FIELD INSTALLED DUCTING TO AND FROM COMPRESSOR CANNOT ADD MORE
THAN 6MM (.25 INCH) OF WATER TOTAL AIR RESISTANCE.
10.UNIT HAS AN INTERNAL DISCHARGE CHECK VALVE, EXTERNAL CHECK VALVE
NOT REQUIRED. ISOLATION VALVE REQUIRED WITHIN 915 MM (36 INCHES)
OF THE COMPRESSOR DISCHARGE.
11.COMPRESSOR SHOULD BE BOLTED TO THE FLOOR WITH FOUR M12 (1/2 INCH) BOLTS
USING HOLES SHOWN ON SHEET 3. SEAL RECEIVER TO FLOOR WITH CORK OR RUBBER.
12.DO NOT PIPE INTO A COMMON HEADER WITH A RECIPROCATING COMPRESSOR. UNLESS
RECIP COMPRESSOR UTILIZES A DISCHARGE PULSATION DAMPENER.
13. DENOTES CENTER OF GRAVITY.
14.SIZING OF ELECTRICAL COMPONENTS NOT SUPPLIED BY INGERSOLL-RAND IS THE
RESPONSIBILITY OF THE CUSTOMER AND SHOULD BE DONE IN ACCORDANCE WITH
THE INFORMATION ON THE COMPRESSOR DATA PLATE, NATIONAL AND LOCAL ELECTRIC
CODES.
15.A BLANK GLAND PLATE IS PROVIDED FOR ELECTRICAL POWER INLET AS INDICATED.
16.WHEN INSTALLED INDOORS IN A CONFINED SPACE, THE COOLING AIR INLET OR
EXHAUST MUST BE DUCTED AWAY FROM UNIT TO PREVENT RECIRCULATION OF HOT
EXHAUST AIR.
CONNECTION LEGEND
- ALL 60 Hz CONNECTIONS ARE NPT (UNLESS SPECIFIED OTHERWISE)
- ALL 50 Hz CONNECTIONS ARE BSPT (UNLESS SPECIFIED OTHERWISE)
A. DISCHARGE AIR: 3/4" INCH (FEMALE)
B. ELECTRICAL INLET: BLANK PLATE SUPPLIED
C. PACKAGE AIR INLET (COMPRESSOR)
D. PACKAGE AIR EXHAUST (COMPRESSOR)
E. PACKAGE AIR INLET (DRYER)
F. PACKAGE AIR EXHAUST (DRYER)
G. CONDENSATE DRAIN 10 MM PUSH-IN (FEMALE)
* OPTIONAL CONDENSATE DRAIN ON NO DRYER VERSION: 1/4NPT
05-Feb-2018 03:39:14 (model D.3/D.5)