Product Manual

22204929 Rev B EN-9
EN
OPERATION
GENERAL
Your air compressor was designed for 100% continuous duty operation
with the use of Ingersoll Rand synthetic compressor lubricant and 60%
continuous duty operation with the use of petroleum lubricant. In other
words, synthetic lubricant allows the compressor to pump continuously
without cycling. Petroleum lubricant limits the compressor to a maximum
of 36 minutes of pumping time per hour. The compressor should not cycle
more than 10 times per hour.
NORMAL START-UP
Set the pressure switch lever to OFF”.
Close the service valve.
Attach hose and accessory.
Move the pressure switch lever to “ON/AUTO”. The unit will start.
Allow tank pressure to build. The motor will stop when tank pressure
reaches cut-out pressure.
Open the service valve. The unit is now ready for use.
NOTICE
When the receiver tank pressure drops below the factory pre-set
minimum, the pressure switch resets and restarts the unit.
1.
2.
3.
4.
5.
6.
WHEN YOU ARE FINISHED:
Set the pressure switch lever to OFF”.
Close the service valve fully.
Remove the air tool or accessory.
Slowly open the service valve to bleed air pressure down to 20 psig.
Slowly open the manual drain valve at the bottom of the tank to
drain all condensate (water).
Close the drain valve and the service valve for the next use.
1.
2.
3.
4.
5.
6.
62215.10.56