Installation guide

% OyS_ @CI O_"
Power Supply Cord
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1=
2.
3=
Disconnect power.
Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove cover
from range.
A. Two mounting tabs each side
B. Terminal block cover
C. Hex-head screws
Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has: And you will be Go to Section:
connecting to:
4-wire receptacle A UL listed, 4-wire connection:
(NEMA type 14-50R 250-volt Power supply cord
minimum,
40-amp, range
power supply
cord
4-wire direct A fused 4-wire connection:
disconnect or Direct wire
circuit breaker
box
(12.7 crn)
3-wire receptacle
(NEMA type 10-50R
A UL listed,
250-volt
minimum,
40-amp, range
power supply
cord
3-wire connection:
Power supply cord
3-wire direct A fused 3-wire connection:
1. disconnect or Direct wire
(2.s circuit breaker
box