User's Manual

iii. Verify Channel Power value of input signal.
F. Connect to RF Cable
G. Connect power supply adapter
Caution: Should check the input power whether 50~88VAC.(For Remote)
Caution: Should check the input power whether 110~230VAC.(For Donor)
H. Testing for calling qualities
5. User Attention
1) Do not open the case of repeater
2) Do not excessive pressure to Repeater.
3) Please use a rated voltage.
4) The repeater must have been installed considering environmental factor.
6. Troubleshooting
1) The PSU LED
Causes Action
Power cable of the power supply unit
has not been connected.
Check connection of power system
Failure of the LED Checking the items of alarm LED
2) The repeater transmits no signal
Causes Action
Coaxial cable connecting the repeater
and measuring system is defective
Replace coaxial cable or power detector
module
Power system of interior of the
repeater has not been connected.
Check power connection of module of
interior of the repeater