User's Manual

JUNI JF43-E1900/CFN03
CDMA FIBER FED REPEATER OPERATIONS MANUAL
Version 1.17 J
uni America Inc. Page 18 of 88
FAN Controller: Turns the FAN On/Off by detecting the internal temperature of the
unit and alerting the Control module () the current status of the FAN .
Duplexer & BPF: Filters out the unwanted signals on the FWD and REV path.
Low Noise Amplifier (LNA): Performs low noise amplification on received signals.
Remote Optic Module: Converts the optic signal (from DHU) into RF signal.
Conversely, it converts the RF signal (from the RU) into an optic signal.
Remote RX SAW Module: Uses the SAW Filter to eliminate all unwanted signals
from the selected frequency and reduces the interference caused by out of band
signals.
Remote Local Module: Generates and provides the local signal required for RU
RX SAW Module ().
Remote TX Drive Module: Amplifies the Forward signal and transmits to the LPA
(), the signal is then amplified once again from the SAW Module() and
transmitted to the Optic Module(). The reverse path performs down conversion of
the frequency to 1330 to 1390MHz for diversity functions.
Power Supply: Converts the input power (55 to 88VAC) into DC+27V, DC+15V, DC
+7V and supplies this power to the modules.
Arrestor: Protects the system against lightning surges. No external lightning
arrestors are required.