User's Manual

JUNI JF43-E1900/CFN03
CDMA FIBER FED REPEATER OPERATIONS MANUAL
Version 1.17 J
uni America Inc. Page 22 of 88
3.4 Inspection before Installing the Repeater
Check if there is any physical damage on the repeater cabinet. If any damage is
found, it is advised to perform close inspection on the operating features and RF
signal test to verify repeater performance.
Check for loose RF cables inside the repeater.
Check whether any part of the cabinet is exposed to water or other liquid substances.
Before installing the repeater, check the serial number of the units to be installed.
Check all required accessories are available.
3.5 JF43 FFR Installation Procedure
3.5.1 Tools and Materials
The following tools and materials are required in order to complete the procedures in
the installation process. The installation processes include RF testing and mechanical
installation.
Portable RF spectrum analyzer or RF power meter
RF Signal generator
AC/DC voltmeter
RF adaptors
External attenuators
RF test cables
PC with Local Maintenance Terminal (LMT) software installed
USB-A to USB-B interface cable
99% pure alcohol
Contraction tubes
Optical TDR (Time Domain Reflectometer)
Wireless terminal
Pencil or pen
Writing pad