DHU Laser Diode does not detect any optic output power.
PD Fault: Displays the alarm state of the Laser Diode. Generates alarm when the
DHU Photo Diode does not detect any optic input power.
Optic RF Fault: Displays the alarm state of the Amplifier of the Optic module.
LD Power: Displays the Laser Diode optic output power.
PD Power: Displays the Photo Diode optic input power.
4. Environment
AC Fault: Displays the alarm state of the main input power of the DHU.
DC Fault: Displays the alarm state of the power supply of the DHU. Generates an
alarm when the DHU power supply detects a fault in its circuit.
Batt Fault: Displays the alarm state of the Battery of the DHU.
Hi Temp: Displays the alarm generated when the detected DHU temperature is
higher than the set Hi Temp.
FAN Fault: Displays the alarm state of the Fan of the DHU.
Door Open: Displays the alarm state of the Door of the DHU.
Low Temp: Displays the alarm generated when the detected DHU temperature is
lower than the set Low Temp.
Hi Temp: Sets/Displays the maximum temperature limit.
Low Temp: Sets/Displays the minimum temperature limit.
Temp: Displays the current temperature of the DHU.
Current: Displays the amount of current consumed by the repeater.
5. DL
DL RF Fault: Displays the alarm state of the Downlink Amplifier.
DL-0 ATT: Sets/Displays the Downlink-0 attenuation. Accurately matches the input
level of the DHU to the optic module dynamic range input.
DL-1 ATT: Sets/Displays the Downlink-1 attenuation. Accurately matches the input
level of the DHU to the optic module dynamic range input.