User Manual

11
4. BAND SETTING
Once the planning of the location and positioning of the Donor and Coverage Units is finalized,
the authorized installer should proceed with installing the Donor and Coverage Units. But first,
the installer should set the appropriate frequency band(s) for the repeater. The figure and table
below show the DIP Switch and the functions for each section. Usually both the PCS and
Cellular bands have to be set up.
After DIP S/W setting, turn power ON/OFF or DIP S/W 12# PIN ON/OFF.
Î DIP Switch Functions
Fig. 6 DIP Switch General Settings
PIN NO. FUNC TION STATUS
1 Cellular Band Selection
ON : Cellular B Band
OFF : Cellular A Band
2
3
4
5
6
7
PCS Band Selection See the next tables below
8 PCS EVDO OFFSET
ON : PCS Gain OFFSET 3dB(increase) ON
OFF : PCS Gain OFFSET 3dB(reduction) OFF
9 Cellular EVDO OFFSET
ON : Cellular Gain OFFSET 3dB(increase )ON
OFF : Cellular Gain OFFSET 3dB(reduction) OFF
10 Band Selection Mode
ON : Software Band Selection Mode
OFF : Hardware Band S election Mode
11 Uplink RF OFF
ON : Reverse RF Power OFF
OFF : Reverse RF Power ON
12 Hardware Reset
ON : Reset
OFF : Normal Operation
PIN NO. FUNC TION STATUS
1 PCS PATH HARDWARE ON/OFF
ON : PCS UL/DL PATH HARDWARE ON
OFF : PCS UL/DL PATH HARDWARE OFF
2 CELLULAR PATH HARDWARE ON/OFF
ON : CELLULAR UL/DL PATH HARDWARE ON
OFF : CELLULAR UL/DL PATH HARDWARE OFF