OWNERS MANUAL Serial No. EDR10488 4/05 Manual Part No.
CONTENTS Advisory ............................................................................................................... 2 Acoustics .............................................................................................................. 4 Installation ............................................................................................................ 5 Troubleshooting .................................................................................................
ADVISORY IMPORTANT INFORMATION READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT This PowerBASE adjustable bed has been quality engineered with design features to assure comfort and safety when operated properly. ELECTRICAL GROUNDING This product is equipped with a polarized, grounded electrical power cord. The power cord will only fit into a grounded, electrical surge protection device (not included) or a grounded electrical outlet.
ADVISORY IMPORTANT INFORMATION READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT This PowerBASE adjustable bed has been quality engineered with design features to assure comfort and safety when operated properly. This bed is designed for in-home use only. It is not approved for hospital use and does not comply with hospital standards. Do not use this bed with tent type oxygen therapy equipment, or use near explosive gases. PACEMAKER WARNING This product produces a vibrating sensation.
ACOUSTICS LIFTING/LOWERING MECHANISMS The lift/lower feature will emit a minimal humming sound during operation. This is normal. During PowerBASE operation, the lift arm wheels make contact with the platform support of the bed. This applies slight tension on the moving components and resonance is reduced to a minimum level. If excessive noise or vibration is experienced, reverse the movement action (up or down) of the bed with the hand control.
INSTALLATION For PowerBASE installation and setup, complete the numbered procedure indicated below and on the following pages: 1.
INSTALLATION 2. Carefully Lift the bed base frame from the shipping carton, keeping the unit top-sidedown. 3. Install (4) legs into the base frame. Simply screw each leg into a tapped hole at each corner of the base frame (FIGURE 1). Insert casters into the bottom of each bed leg (if applicable). POWER DOWN BOX BATTERY COMPARTMENT DOOR CASTERS – PRESS-FIT INTO BOTTOM OF LEGS (IF APPLICABLE) FIGURE 2: Power down box battery compartment door removal.
INSTALLATION 10. Install mattress retainer as follows: a. Install (1) cupped washer, (1) spacer and (1) flat washer on (4) mattress retainer bolts (FIGURE 4). B d. Tighten screws to complete mattress retainer installation (FIGURE 6). ASSEMBLE AS SHOWN BELOW: D CUPPED WASHER SPACER A C MATTRESS RETAINER HARDWARE KIT CONTAINS: (4) MATTRESS RETAINER BOLTS - A (4) FLAT WASHERS - B (4) SPACERS - C (4) CUPPED WASHERS - D FLAT WASHER MATTRESS RETAINER BOLT FIGURE 4: Mattress retainer hardware.
INSTALLATION 3 in ch M es AX . USE (2) 3 INCH CARRIAGE BOLTS AND NUTS TO ATTACH EACH BRACKET CHANNEL TO BED BASE FRAME EXTENSION ANGLE BRACE SLIDE HEADBOARD BRACKET CHANNEL OVER THE BED BASE FRAME EXTENSION FIGURE 7: headboard cross member location must not exceed 3 inches (76.2mm) from the top of the mattress. 12. Install headboard bracket assemblies per the following procedure: a. Raise the head section of the bed (with hand control) to gain access to the bed base frame. b.
INSTALLATION d. Slide headboard bracket assemblies (in or out) to achieve a distance of 1.5 inches (38.1mm) to 2 inches (50.8mm) between the edge of the bed base and headboard bracket flange assemblies (FIGURE 11). e. Firmly tighten the 3 inch carriage bolts of both headboard bracket channels. f. Measure the distance (center-tocenter) between the mounting holes in the headboard. g. Measure the center-to-center distance between the mounting slots of the headboard bracket flanges (FIGURE 12). h.
TROUBLESHOOTING In the event the PowerBASE adjustable bed fails to operate, investigate the symptoms and possible solutions provided in the chart below: SYMPTOM Hand control illuminates and appears to be operable, but will not activate bed. SOLUTION • Verify power cord is plugged into a working, grounded electrical outlet. A grounded, electrical surge protection device is recommended. Test outlet by plugging in another working appliance.