Instruction Manual

- 24 -
The LM Programmer software then shows in its first page the type and version number of the
firmware of the device.
13.1 Changing the device name
If multiple DL-32’s are used in a Log-Chain, each MUST be given a unique name so that
LogWorks can identify each DL-32. Just enter a name in the edit box in this page.
13.2 Updating the firmware
Click on the ‘Update Firmware’ button. You will be presented with a file dialog box that allows you
to select a firmware file. Firmware files end with the file extension .dld.
DL-32 firmware file names start with: DL32. The first part is followed by a dash, then a V, then
the version number without dots.
Example: DL-32 firmware version 1.00 alpha release would have the file name DL32-V100A.dld
DL-23 firmware version 1.00 would have the file name DL32-V100.dld
After you opened the firmware file, this new firmware will be downloaded in the DL-32 device.
13.3 Input 1 Configuration
Click on the Input 1 tab in the top of the window.
13.3.1 Measuring RPM