User Manual

13-2 Timer LC 1200 Manual
Wiring
You will need 22-gauge, 4-conductor plenum-
rated cable for this connection.
To wire the Timer to the LC unit, refer to Figure
13.2 and use the following instructions:
1. Using the BLACK wire, connect the “-
pin of the Timer to P3-pin5 (Ground) of
the LC unit.
2. Using the RED wire, connect the “+
pin of the Timer to P3-pin4 (+12V) of
the LC unit.
3. Using the WHITE wire, connect the
N.O” pin of the Timer to P1-pin2
(Perimeter In) of the LC unit.
4. Using the GREEN wire, connect the
C” pin of the Timer to P1-pin1
(Perimeter Out) of the LC unit.
Figure 13.2 Wiring the Timer