LC 1200 Manual FAQ & Troubleshooting 16-3
Troubleshooting
A Tag is not being detected by the monitored
zone.
1. Use a TAD to verify Tag is active.
2. Use a TAD to verify Tag battery is
sufficient.
3. Verify proper zone coverage (page 3-3)
4. Verify proper zone wiring of LC unit
I am getting an abundance of nuisance alarms.
A nuisance alarm is undesired alarm activation
stemming from such things improper zone
coverage and the improper storage of Tags.
1. Verify proper zone coverage. Proper
zone coverage fully protects the
intended area without extending into
other areas (see page 3-3 “Verifying
proper zone coverage” and page 2-8
“Adjusting the Tx Activation Field”).
2. Be sure proper Tag storage techniques
are followed (see page 3-2)
When I escort a patient through a zone via a
Keypad Reset, the Reset time allotted is too brief
and an alarm occurs.
Adjust the Keypad Escort time to accommodate
slower moving patients (see page 6-9)
An alarm has occurred and I am addressing the
alarm but the internal piezo buzzer will not
cease.
1. After you have identified the cause of
the alarm and are addressing it, you may
silence the internal piezo buzzer by
removing the LC unit cover and jumper
JP2 (Tone Enable).
I am getting a Tamper alarm after initial
installation or service. What am I doing wrong?
Verify the Tamper Switch (S1) is making good
contact with the outside case (see Tamper
Switch adjustment; page 2-7).