User Manual

Accutech reserves the right to substitute comparable components without notice.
R051903
M090503
CUT SHEET: Automatic Door Deactivation
In automatic door applications (doors that open via a motion sensor or push paddle), the Accutech System can deactivate this
feature when a Tag enters a monitored zone’s Tx Activation Field.
ELECTRICAL:
Operating Voltage: 12V DC
Current Consumption: 120 mA maximum
Contact Rating: 100 mA / 12V DC
Cable: need minimum 22-gauge, 6-conductor
MECHANICAL:
Construction: Metal case
Enclosure size: 6.00” x 6.00” x 4.00”
Enclosure weight: 3.85 US pounds
OPERATING CHARACTERISTICS
Dry contacts are provided for the automatic door
company’s use.
ENVIRONMENAL:
Operating Temperature: 32º to 120º Fahrenheit
Intended for indoor use only.
DUTY CYCLE:
Rated for continuous use.
Automatic Door Deactivation
Model Number: ADD
800-356-2671 | Accutech | www.accutech-ics.com