Programming user codes
Remember that user code No. 01 will become
the new master code as soon at it is
programmed, and therefore should be assigned
to the person in charge of security.
It is recommended that the master code be
composed of at least 8 digits.
To program user codes, use the following
instructions:
1. Prepare a list of user codes you want to
program and record them.
2. Invoke the programming menu by
entering **, [master code], **. At this
point we shall assume that the factory
default of 1234 is still valid. When the
programming menu is active, the green
LED flashes slowly, approximately once
every two seconds.
3. Press 1 to select user code programming
(function No. 1).
The green LED begins to flash rapidly
(approximately 5 times per second),
indicating that the Keypad is ready to
receive data.
NOTE: To prevent programming by
unauthorized people, it is dangerous to
continue using the default master code
1234. It is mandatory to set a new
master code, which will be used for
programming only and not for everyday
requirements. We recommend that the
master code be comprised of at least 8
digits.
4. Enter user number 01, followed by #.
The green LED lights steadily for two
seconds and then returns to rapid
flashing indicating that the step has been
completed successfully.
5. Enter the code assigned to this user,
followed by #.
The green LED lights steadily for two
seconds and then returns to rapid
flashing.
6. Repeat the user code followed by #. The
green LED will acknowledge as in the
step above.
7. Now select which outputs will be
tripped by the new master code, select 3
for all outputs and then press #.
This time the green LED lights steadily
for two seconds and then flashes slowly,
indicating that the new master code and
its extent of control have been
programmed successfully and that the
Keypad has returned to the
programming menu. Now you can either
program the next user code or quit
programming by pressing #.
8. Repeat these steps to assign other user
codes.
NOTES:
Do not enter new data if the green LED
responds by going out for 3 seconds after having
pressed [#]. If the Keypad detects an error, the
green LED turns off for 3 seconds and then
returns to slow flashing, thus indicating that the
data has not bee accepted. It would be necessary
to repeat the entire programming sequence for