User's Manual

Installation Manual Appendix B-3
JP12 (Loiter Time Extend Disable)
Factory Default IN
This jumper determines the timing range of
the Loiter Timer potentiometer (R110)
Table B.7 JP12
Position Time Range
In 10-60 seconds
Out 65-110 seconds
JP13 (Piezo Enable)
Factory Default IN
This jumper controls whether the piezo is
enabled or disabled.
Table B.8 JP13
Position Piezo is:
In Enabled
Out Disabled
JP14 (Bar Display Enable)
Factory Default IN
This jumper will enable the bar display
LED 13 to function for installing or testing
purposes.
JP15 (TX Output LED Enable)
Factory Default IN
This jumper will enable the Tx Output LEDs
(LED1, LED2 and LED3) for installing or
testing purposes.
JP16 (Door Ajar Reset)
Factory Default IN
This jumper will determine whether the
Door Ajar alarm automatically resets.
Table B.9 JP16
Position Door Ajar Automatically Resets?
In Yes
Out No