Installation Manual User-Defined Settings 22-1
User-Defined Settings
Door Ajar
Door Ajar Reset
Loiter
Loiter Reset
System Supervise
Power Loss Supervise
NOTE:
The following settings are up to the
facility’s discretion. All times are approximate.
Door Ajar
A Door Ajar alarm occurs when a door is open
for longer than the preset time. By setting a
delay using R97 and JP11, you can adjust the
time (from 10 to 110 seconds) necessary before
a Door Ajar alarm occurs preventing nuisance
Door Ajar alarms from air flow or slight bumps
to the door.
R97 (Door Ajar Delay)
Factory Set to 15 seconds
Set mid scale or as desired to delay onset of
Door Ajar alarm.
JP11 (Door Timer Extend Disable)
Factory Default IN
This jumper determines the timing range of the
Door Ajar Time potentiometer (R97).
Table 22.1 JP11
Position Time Range
In 10-60 seconds
Out 65-110 seconds
Door Ajar Reset
JP16 determines if the Door Ajar automatically
resets once the door is fully closed.
Table 22.2 JP16
Position Door Ajar Automatically Resets?
In Yes
Out No
Loiter
A Loiter alarm occurs when a Tag lingers in the
Tx Activation Field for longer than the preset
allotted time. By setting a delay using R110 and
JP12, you can adjust the time necessary (from 10
to 110 seconds) before a Loiter alarm occurs
preventing nuisance Loiter alarms from normal
resident movement or passersby.
R110 (Loiter Delay)
Factory Set to 15 seconds
Set mid scale or as desired to delay onset of
Loiter alarm.
JP12 (Loiter Time Extend Disable)
Factory Default IN
This jumper determines the timing range of the
Loiter Timer potentiometer (R110)
Table 22.3 JP12
Position Time Range
In 10-60 seconds
Out 65-110 seconds