1 Overview
The EN1240-60 activity sensor is designed specifically for residential and
senior living environments where a notification of a daily activity is
necessary. The EN1240-60 leverages the latest motion detector
technology, including white light and pet immunity, to ensure performance
accuracy. Selectable fixed sleep intervals of two, four, or six hours are used
to minimize wireless traffic in large installations, while confirming daily
resident activity. Check-in messages are sent every 60 minutes to provide
effective notification of recent resident activity even when the device is in
the fixed sleep cycle.
Note: For UL 2560 installations, refer to the EN6080 Area Control Gateway
Installation Instructions.
Note: In UL 2560 installations, transmitters send a check-in message every
60 minutes.
Caution: The EN1240-60 needs one minute for stabilization after power
up. During the stabilization period, the LED will blink twice per second, and
the EN1240-60 will not be operational.
Caution: Prior to operation, the EN1240-60 must be acclimated to the
temperature of the install environment for a period of 60 minutes.
Caution: The EN1240-60 activity sensor is not designed for use as a
security system motion detector.
1.1 Maximum Number of Repeaters for a UL 2560
Installation
To achieve the 99.99% alarm message reliability required for UL 2560
compliance, system installations must operate within the following limits for
end device and repeater counts.
1.2 Inovonics Wireless Contact Information
If you have any problems with this procedure, contact Inovonics Wireless
technical services:
E-mail: support@inovonics.com
Phone: (800) 782-2709; (303) 939-9336
1.3 EN1240-60 Internal Components
Figure 1 EN1240-60 components
1.4 What’s In The Carton
Three wall mount screws
Three wall mount anchors
One selection jumper
One 3.0V lithium battery
2 Installation and Startup
2.1 Installation Notes
These products are designed to be installed and maintained by
professional security technicians.
Products are intended for indoor use.
Manually test all products weekly.
End Devices Maximum
Repeaters
150 397
250 386
350 375
500 360
1000 313
2000 238
3000 184
A Frequency band
selection pins
B Reset button C Pulse count selection
pins
D Pet immunity selection
pins
E Test mode reed
switch
F Sleep duration
selection pins
G Sensitivity adjustment
dial
H Battery I Case tamper switch
J Sleep duration selection
pins
K Sleep time
selection pins
C
A
D
B
E
G
F
H
I
K
J

Summary of content (4 pages)