Owner's manual

FA210 / FA210W / FA210M
Frequency Agile
®
900MHz
Reduced-size
Universal transmitter
Mounting the FA210
Reduced-size universal transmitter
FA210 Programming
1. Connect cable from programming
device to programming header on
transmitter.
2. Press Reset button on transmitter.
3. Disconnect cable.
Technical Support
Phone 800.782.2709
Inovonics Wireless Corporation
315 CTC Blvd
Louisville CO 80027
www.inovonics.com
LIT-FA210-INSTALL 03396C.DOC 11-Jan-06
1. Mount the bracket on the
wall with the screws
provided. Screw heads
must be flush or slightly
recessed. (A #8 drywall
screw can also be
used.)
2. Clip the transmitter onto
the bracket. Hook the
bottom catch first, then
press the top into place.
FA210M
Instant Response Transmitter
The FA210M provides an instant response to a
momentary closure on the input terminals. A
1.5 second closure is not required as with the
standard FA210.
The transmitter will only operate properly when
programmed as a normally open input device. End of
Line Resistor and Internal Contacts are not
supported.
3. The housing may be secured to the bracket
with a third mounting screw, located
beneath the battery. Accessing this screw
on an active transmitter requires opening
the housing and removing the battery,
causing a tamper condition (if monitored).
4. To dismount the FA210, pull the transmitter
housing carefully out of the mounting
bracket from the top.
5. An EOL resistor is shipped with the
transmitter for optional tamper resistance.
If desired, attach the EOL resistor.
NOTE: FA210, FA210W and FA210M transmitters
do not require reprogramming after loss of
power They retain programming data in non-
volatile memory. Install new battery and
press reset button to re-initialize the
transmitter
Receiver Programming: The FA116 programmer must be used
to enable the internal contact feature when programming the
FA210/FA210W to FA464DR or FA416 receivers. The FA210W
“widegap” feature cannot be used on FA404 or FA401 receivers.
An alarm transmission is caused by providing a
momentary switch closure to the input. Typical
required time is 10 milliseconds, but during the
battery test (every 18 hours) the required closure time
can be as long as 100 ms. In life-safety applications
the 100 ms spec should be followed.
To conserve battery life, the momentary closure
should not be greater than 4.0 seconds.
© Inovonics Wireless Corporation 2001
Specifications
External contacts: N/O or N/C
Wire gauge: 14-22 AWG
Distance, external switch to FA210(W): 10 feet , maximum
Minimum contact closure duration: 1.5 seconds
Internal contacts (FA210W only): as needed
EOL(FA210, FA210W only):: as needed
Typical battery life: 4 years
Battery (BAT604): 3.0V Panasonic CR123A (or
approved equivalent)
Battery part #: BAT604
Operating environment: 32 to 140°F (0 to 60°C)
The FA210W has 2 internal contact magnetic reed switches. The
switches are located to permit either horizontal or vertical
mounting of the FA210W unit. The FA210W can monitor internal
and external contacts at the same time. Maximum operating gap
for the FA210W is 5/8".
NOTE: Inovonics products are intended to be
installed by professional security technicians.