FA416 / FA416D FA416R / FA416DR Frequency Agile® 900MHz 16-Channel / 4-Output Receiver Installation Instructions 02304E Document revision history Rev. Level Description Date C Create F:\Eng\parts\02304\02304C.doc from P:\Master.dox\FA_dox\FA416_v3.doc 7/19/01 D Replace ISO logo 10/08/01 E Page 5: replace “95%” with “90%” Page 6: add “effectively reverses relay polarity” Page 10: replace “access code to 3446” with “System ID” 10/29.
Overview: • • • • • The FA416 receiver is a high performance wireless receiver with 4 configurable alarm outputs and 1 global fault output. The FA416 has default settings which permit 4 transmitters to be programmed to it. Two of these transmitters may be normally open devices; two may be normally closed devices or have normally closed contacts. The FA416R and FA416DR have 5 onboard Form C relays. In all other respects they are identical to the FA416 and FA416D.
Figure 2: FA416R / FA416DR receiver Advance Button FA104 Programmer Port Delete Button ADV DEL 13.
Features of the FA416 include: • Fully supervises up to 16 FA transmitters. • Outputs can be configured Normally Open or Normally Closed via Output select jumper. (One configuration for all outputs.) • For N/O configuration, output is open relative to ground. On activation, output pulls to common ground. • For N/C configuration, output is held at common ground. On activation, output releases to open circuit.
Technical Specifications: Dimensions (housing): 6.38" x 3.60" x 1.10" Weight: 6.9 oz.
Connecting FA416-version receivers to a panel: When the FA416 will be used with a hardwire security panel, the panel will supply 12VDC power and ground to the FA416. Typically, the ground supplied to the receiver is common to the input loops of the hardwire panel. NOTE: Ground from the panel to the receiver MUST be common on the FA416 and FA416D. Otherwise, the FA416R or FA416DR must be used. Receiver outputs are connected by one wire each to their respective zone input loops on the panel.
Programming transmitters: Refer to "Overview", page 2, for a description of programming features. This section describes programming transmitters by directly connecting them to the receiver. Note that the FA116 programmer permits users to change all receiver and transmitter options. Default programming without the FA516 display module: Transmitters are connected to the FA416 with the programming cable.
Receiver Operation: Output activation: Outputs will open or close upon activation of the point. This function is determined collectively for all outputs by placement of the Output Select Jumper. (If the jumper position is changed after transmitters have been programmed, it will be necessary to press the receiver Reset Button.) Activation of an output is indicated by the corresponding Output LED on the FA416 board. The fifth LED is the Global Fault LED.
Resetting outputs: All outputs can be reset either by pressing the Reset button or by pulling the Reset input terminal to ground. This can be done by installing a switch between the reset input and the ground terminal on the receiver. Remote or automatic resetting can be accomplished by relay control from the hardwire panel. All outputs are cleared.
• The transmitter is programmed, but is not tripping the output. Try programming the transmitter again. If you have an FA116 programmer, check the output assignment. Check the signal level to make sure the device is transmitting. See if the transmitter works nearer to the receiver. • An output other than the one indicated in Appendix B is being activated. The receiver's output configuration may have been reprogrammed. Use an FA116 to confirm this, and to make changes as needed.
Appendix A: Default Receiver Parameters Output 1 2 3 4 Active on Condition Alarm Alarm Alarm Alarm Transmitter Condition Default Mode Alarm Inactive Tamper Low Batt Programmable Options Alarm / Alarm+Tamper / Disabled Alarm / Alarm+Tamper / Disabled Alarm / Alarm+Tamper / Disabled Alarm / Alarm+Tamper / Disabled Follower Follower Latching Latching Follower / Momentary / Latching Follower / Momentary / Latching Follower / Momentary / Latching Follower / Momentary / Latching Default Momentary Output
Appendix C: FA200 Universal Transmitter Frequency Agile™ Series Transmitters FA200W FA202 Universal Widegap Transmitter Smoke Detector Reset button Reset button Programming Header Reset Button Programming header Programming header B a t t e ry B a tte r y Tamper switch Widegap reed switch Tamper switch Battery terminals Program contacts: EOL resistor: Typical battery life: Battery type: Battery terminals N/O or N/C, as needed as needed 3 years 4.
Frequency Agile™ Series Transmitters (Continued) FA209 Billtrap Transmitter FA210 Reduced-size Universal Transmitter FA210W Reduced-size Universal Widegap Transmitter Programming header Reset button + + Delay selector 3.0V 3.0V FA210W Widegap Reed switches Tamper switch Reed switch indicator 3V LITHIUM 3V LITHIUM Tamper switch Reset button Programming header Program contacts: EOL, internal contacts: Typical battery life: Battery type (Qty. 2): Dimensions: N/O No 1-2 years 3.
FA416 PROGRAMMING WORKSHEET DATE: COMPANY: ADDRESS: CITY: PHONE: ATTN: Default Receiver Output Parameters Default Output Active on 1 Alarm Alarm 2 Alarm Low Battery 3 Alarm Tamper+Inactive 4 Alarm Disabled Default Transmitter Output mode Condition Default Mode Alarm Follower Follower Inactive Follower Follower Tamper Latching Follower Low Batt Latching Follower Default Momentary Output time: 4 seconds Programmable Output time: 1 - 16 seconds Default Receiver Parameters System ID: Point supervision: Superv
Inovonics Wireless Corporation ("Inovonics") warrants its products ("Product" or "Products") to conform to its own specifications and to be free of defects in materials and workmanship under normal use for a period of twenty-four (24) months from the date of manufacture. Within the warranty period Inovonics will repair or replace, at its option, all or any part of the warrantied product. Inovonics will not be responsible for dismantling and/or reinstallation charges.
Frequency Agile® Receivers from Inovonics: FA401 FA401R FA404 FA404R FA416 FA416D FA416R FA416DR FA464DR Single Channel / Single Output Single Channel / Single Relay Output 4-Transmitter / Single Output 4-Transmitter / Single Relay Output 16-channel / 4-output 16-channel / 4-output with display 16-channel / 4-relay output 16-channel / 4-relay output with display 64-channel / 16-relay output with display Receiver Accessories: FA116 FA516 FA541 Executive Programmer for FA416 / FA464 / C404 Display module f