5G INDUSTRIAL GATEWAY S2000e USER GUIDE 37
If you select Enable Ignition Sense:
Ignition Sense Options: Select an option from the drop-down:
Ignition Time-Voltage Based Shutdown Allows you to specify an amount of time
and battery level. When the ignition is turned off, the device stays on until one of the
thresholds is met, at which point it shuts down.
Ignition Time Based Shutdown Allows you to specify the amount of time you want
the S2000e to remain on after the ignition is turned off.
Ignition Voltage Based Shutdown - Voltage Level: Allows you to specify the battery
level at which you want the S2000e to turn off.
Shut down after: Enter the number of minutes you want the S2000e to stay on after the
ignition is turned off.
Shut down when external battery reaches: Enter the number of volts to use as a battery level
threshold. When the battery reaches that amount of voltage, the S2000e will shut down.
If you select Enable Digital I/O:
Input Setting: Select Input or Output.
NOTE: Input can be Input, used to tell the S2000e the state of an external device or system.
Output is used to turn another device or system on (low) or off.
I/O Setting Name: Enter a user-friendly name for the setting.
Low State Name: Enter a user-friendly name for the low state.
High State Name: Enter a user-friendly name for the high state.
Current State: The current state of the pin: low or high.
Create Banner Alert in UI: Select an option for state change alerting in Inseego Connect.
Pin 4 Digital I/O
Digital I/O Setting: Use the drop-down to enable or disable Pin 4.
Digital I/O options are the same as for Pin 3.
Advanced Tab
Advanced settings are intended only for users with advanced technical knowledge. For information
about the Advanced Settings page, go to Chapter 4, Advanced Settings on page 47.