User's Guide
Table Of Contents
- 1. Product Overview
- 2. UI Reference
- Support
- Admin Password
- Wi-Fi - Settings
- Wi-Fi – Primary Network
- Wi-Fi – Guest Network
- Wi-Fi – Wi-Fi as WAN
- Connected Devices
- Access Control - Devices
- Access Control - Schedules
- Settings - Preferences
- Settings – Software Update
- Settings – Backup and Restore
- Advanced Features – Lan
- Advanced Features – Network
- Advanced Features – Manual DNS
- Advanced Features – Firewall
- Advanced Features – MAC Filter
- Advanced Features – Port Filtering
- Advanced Features – Port Forwarding
- Advanced Features – WAN Configuration
- GPS - Status
- GPS - Local
- GPS - Remote
- GPIO
- VPN
- Remote Management
- About – General Status
- About – Primary WAN
- About - Ethernet WAN
- About – Wi-Fi as WAN
- About – System Status
- 3. Using, Testing, Troubleshooting
- 4. Regulatory Information
User Guide
Skyus 500 (Ninkasi)
Rev 1 Page 69 of 78
inseego.com
Package Size – What is sent?
When device powers up, all data points are sent in check-in data. After which, only those that vary
like RSSI is sent and static ones are not sent like ICCID, MDN, IMEI etc. (Hardware data)
Variable = Measurement (Graphs are drawn)
Static = Inventory (One Time Data)
We are currently trying to estimate the range of package size sent in different data traffic modes
* Disabled – Packet Size = 0
* Enabled – Packet Size = Assuming its 1MB (More like 0.3MB)
* Low Data Enabled – Packet Size = Assuming its 0.4MB (More like 0.1MB)
Test Scenario
RSA: ON
IOTC: firmwaretest.cumulocity.com
Check-in Interval: 15mins
1. Connect over WiFi >> Run sysintcli getDataUsageStatistics >> SSH to set tcpdump
tcpdump -i eth1 -s 65535 -w /root/eth1.pcap &
2. Disconnect WiFi
3. No pings/traffic, device is connected to Charger - Device is set aside for an hr
4. Connect over WiFi >> Use WinSCP to grab eth1.pcap >> Run sysintcli
getDataUsageStatistics
sysintcli getDataUsageStatistics --> Gets tx and rx bytes
Test Steps
• Log-in to device, configure, disconnect from device
o 1 hour, RSA ON, No sensors -> Filter on port 183 on Cumulocity server ->
Total Data Usage
o 1 hour, RSA ON – LDE, No sensors
o 1 hour, RSA OFF
• Repeat test 1 & 2 with one of each sensor type (if supported)