SET_STATUS
Use
This command sets configuration parameters and coupler’s I/O :
" Communication speed
" Protocols
" State at Power ON
" 2 outputs & 1 input
The various parameters and data used by INSIDE couplers are stored in the EEPROM.
When coupler is powered on, a part of these parameters are load in coupler’s RAM, so
that parameters may be modified in coupler’s EEPROM and in coupler’s RAM.
For a given parameter, RAM and EEPROM address are the same. For example, speed
parameter is located at address 6Dh for both RAM and EEPROM.
! When updating a value in the coupler’s EEPROM, this value will be the default
value after turning the coupler on.
! When updating a value in the coupler’s RAM, this value will be the current value
until the next Power Off.
! When writing to EEPROM occurs, EEPROM parameters are reloaded into processor
memory (RAM).
Prototyping
" Command sent : F4h
" Command type : ISO In
Host
80hF4hP1 P201h Data
Coupler
F4h 90h 00h
Parameters
P1: Sets the type of configuration parameter to update
b7 b6 b5-b2 b1 - b0
Reset coupler
Reset magnetic
field
- (RFU) Address
b7 : Resets coupler
if this bit is set to 1, coupler will fully reload EEPROM in RAM as if the coupler is powered
on.
Note : when b7 = 1, the coupler responds 3Bh 00h.