Chips and readers- USER’S GUIDE
UG 8
Version 1.0
HALTING A CHIP
The following command halts the current selected chip :
!!
!!
! ActiveX method : Mx.Halt
!!
!!
! C Library : Clib_w_Halt (protocol)
!!
!!
! Low level : TRANSMIT command + 00h chip command
Host
80h C2h 31h 00h 01h 00h
Coupler
C2h 90h 00h
TIPS : to halt the chip
as soon as you get its
serial number, use P1
parameter in the
SELECT_CARD
command
Note : To use another protocol, just change the appropriate bit in P2
parameter :
14 443 B-2 : Use 80h C2h 30h...
14 443 B-3 : Use 80h C2h 32h...