Data Sheet
Preliminary Data Sheet 
April 23, 2020 
Page 6/25 
Document Ref: isp_ble_DS1907_R4.docx 
Insight SiP 
– Green Side – 400  avenue Roumanille – BP 309 – 06906  Sophia-Antipolis Cedex – France –
www.insightsip.com 
BLE MODULE 
ISP1907 
2.4.  Power Consumption 
Parameter 
Typ / LL variant 
Typ / HT variant 
Unit 
Radio current, Receiver active
 (1)
6.1 
6 
mA 
Radio current, Transmitter active -40 dBm Output Power
 (1)
3.4 
3.5 
mA 
Peak current, Transmitter active 0 dBm Output Power
 (1)
5.8 
6.1 
mA 
System OFF, no RAM retention, wake on reset 
0.3 
0.4 
µA 
System ON, full RAM retention, wake on any event 
0.8 
1.7 
µA 
(1) DCDC enable, Power supply 3V, 1 Mbps
2.5.  Clock Sources 
Parameter 
Max 
Unit 
Internal High Frequency Clock for RF Stability: 
32 MHz Crystal Frequency Tolerance 
(1)
+/- 40 
ppm 
Internal Low Frequency Clock for BLE Synchronization: 
32.768 kHz Crystal Frequency Tolerance 
(1)
+/- 40 
ppm 
Internal Low Frequency Clock for BLE Synchronization: 
RC Oscillator 
(2)
+/- 500 
ppm 
RF Frequency tolerance: 
For BLE operation Channels0 to 39 
+/- 40 
ppm 
(1) including initial tolerance, drift, aging, and frequency pulling
(2) Frequency tolerance after calibration
2.6.  Radio Specifications 
Parameter 
Min 
Typ 
Max 
Unit 
Operating Frequencies 
MHz 
RF Channel spacing 
1 
MHz 
Data Rate 
125 
2000 
kbps 
RF Output Power, LL variant 
-20
+4
dBm 
RF Output Power, HT variant 
-20
+8
dBm 
Rx sensitivity Level 1 Mbps BLE mode, ideal Tx 
-94
dBm 
Rx sensitivity Level 125 kbps Long Range mode, ideal Tx 
-104
dBm 
Antenna Gain 
dBi 
Range Open field, BLE mode @1m height 
100 
m 
Range Open field, Long Range mode +4 dBm @1m height 
400 
m 
2402 2480
 1
Specification subject to change without notice.