Specification Sheet

SYPHON BREAKER
Prevents back flow of contaminated water into water line.
SOLENOID VALVE
Activated when disposer is turned on. Insures water is in grind chamber
when disposer is running. Deactivates when disposer is turned off.
FLOW CONTROL VALVE
Automatically controls the proper amount of water to the disposer for
trouble-free operation while limiting excessive water consumption. The
valve has an arrow indicating flow direction, and has the GPM (gallons per
minute) rating marked on the part. The recommended valve for
InSinkErator disposers is as follows:
MODELS H.P. STANDARD OPTIONAL
*
SS-50, SS-75
½, ¾ 3 GPM 3 GPM
SS-100, SS-125 1, 1
¼ 5 GPM 3 GPM
SS-150, SS200 1
½, 2 7 GPM 5 GPM
SS-300, SS500 3, 5 8 GPM 7 GPM
SS750, SS1000 7
½, 10 10 GPM 10 GPM
*Optional low water consumption flow control valve may be
substituted if water is present from another source, (example: overhead
spray) or in a new installation with a short run to the sewer line. Consult
InSinkErator factory for more information.
Note: Flow Control Valve, Syphon Breaker, and Solenoid Valve are
included at no charge when a complete disposer package is ordered.
TIME DELAY RELAY
Provides delay of solenoid valve shut-off to provide a post flush to help
prevent drain line stoppages. Beneficial when ground food waste must
travel through many bends or a long horizontal run. Adjustable from 0 to 10
minutes.
ACCESSORIES
PROJECT: ITEM NO.:
© InSinkErator Printed in USA Form No. F186-06E-19-02
InSinkErator is a division of Emerson Electric Co.
4700 21st STREET
RACINE, WI 53406
TEL: 800-845-8345
FAX: 262-554-3620
www.insinkerator.com
The Emerson logo is a trademark and a
service mark of Emerson Electric Co.
Our products appear on The KCL CADalog
CD-ROM based CAD Foodservice Symbol
Library. More information is available from
Kochman Consultants, Ltd.
at www.kclcad.com.

Summary of content (1 pages)