Series 2200 Series 1100 Instant Hot Water Dispenser Owner’s Manual Installation, Care & Use Instalacion, cuidado & uso Installation, soin et utilisation
® We are delighted that you have chosen the InSinkErator® Instant Hot Water Dispenser to be a part of your home. This unique appliance will save you time and effort in the kitchen, and you’ll enjoy discovering new uses for it each day. That’s exactly why millions of people are now using an InSinkErator Instant Hot Water Dispenser. We are confident that by following our step-by-step instructions, you’ll soon be enjoying the convenience of instant hot water.
Identify the model of your instant hot water dispenser and record it here:________________ F-HC2200 F-GN2200 F-HC2215 F-GN2215 F-HC1100 F-GN1100 HOW TO USE THIS INSTRUCTION MANUAL These instructions are separated into main sections, indicated by numbers, and subsections, indicated by capital letters. The manual is setup this way to allow you to take a break at any point after completing a section or subsection without affecting the installation process.
COMPONENTS IN THIS PACKAGE F-HC2200 F-GN2200 F-HC2215 Rubber O-Ring Hex Nut Semi-circular Mounting Plate Hex Tool F-GN2215 F-HC1100 F-GN1100 Plug (1) Quick Connector Filter Head 3/8" Tubes (2) SST-FLTR 4 Brass Nut / Ferrule / Tube Insert Filter Cartridge Snap-Connect Fitting (3 pieces) Filter Discharge Tube 3/4" Screws (4)
IF INSTALLING ONLY NEW FAUCET A Q Determine if your existing tank is A, gray plastic shell, or B, white metal shell. Release Ring Release Tab 1/4" blue 7/16" 5/16" white clear Tank A 1/4" blue or copper 5/16" clear 7/16" white Tank B Q At tank top, depress gray release tab (if A) or release ring (if B) into quickconnect fitting securing blue or copper 1/4" tube and gently pull line out of fitting. Pull white 7/16" tube and clear 5/16" tube off fittings.
START HERE 1A PROPER INSTALLATION SHOULD TAKE ABOUT 2-4 HOURS PREPARATION Required minimum from center of hole to wall F-HC2215................31⁄8" F-GN2215................37⁄8" F-HC2200................31⁄8" F-GN2200................37⁄8" F-HC1100................31⁄8" F-GN1100................43⁄8" Maximum counter thickness is 3". Q Identify locations for the dispenser faucet, tank and filter. Q Check to make sure there is proper clearance for dispenser handles to be fully opened.
2A INSTALLING THE FAUCET Q Unpack dispenser components. Q On a firm, flat surface, carefully straighten the copper tubing. Property Damage: Do not pinch or break copper tubing. Do not distort the last 1 inch of tubing. B Q Ensure that the black O-ring is properly seated in the base of the dispenser head (the groove on the underside of the dispenser). Make sure to use rubber O-ring to ensure proper seal.
3A MOUNTING THE TANK Q Select a spot under the sink to mount Tank must be mounted level to ensure proper operation. tank vertically within reach of both plumbing and electrical connections. The tank should be within 16" or less of faucet water lines and within 30" or less of a standard grounded outlet. Q While holding tank in place on Property Damage: Tank must be located within 16" of faucet and within 30" or less of a standard grounded outlet. DO NOT extend plumbing or electrical lines.
5A INSTALLING FILTRATION SYSTEM Q Mark hole locations for filter head and bracket in a spot that allows for filter replacement. Q Drill 1/8" starter holes and attach bracket to wall with wood screws, turning until snug. Q Remove red filter cap, insert filter Personal Injury: Do not locate filter above an outlet or other electrical device. Install head and bracket so that connections require no stretching, kinking or pinching of tubing.
6A FINAL WATER CONNECTION Q Install a T-fitting (not included) Brass Nut Ferrule Brass Insert Plastic tube Property Damage: Join remaining tube to cold water supply only. B onto the cold water supply line. Q Install dedicated water control valve with 3/8" compression fitting. Q At the end of the white 3/8" tube from the filter or quick-connector, slide the supplied brass nut and ferrule over the tube and then push in the brass tube insert.
Electric Shock Hazard: Using an ungrounded or improperly connected appliance can result in serious injury or death from electrical shock. This appliance must be grounded. This instant hot water dispenser is equipped with a cord that has a grounding conductor and a grounding pin. The plug must be connected to an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
CARE AND USE Electric Shock Hazard: To prevent electrical shock, disconnect power before servicing unit. Use only a properly grounded and polarized electric outlet. ADJUSTING THE THERMOSTAT Factory temperature pre-set is 200˚F. To reset the thermostat to 200°, turn the indicator one notch to the right of vertical. approx.
FILTRATION INFORMATION The InSinkErator Instant Hot Water Dispenser Filtration System is intended for use in filtering sediment, chlorine taste and odor from drinking water, and has not been evaluated for other uses. The system is typically installed (near or beneath a sink) where filtered drinking water is desired, and must be installed, operated and maintained as specified in the installation and use instructions.
Please read Troubleshooting Guide and/or visit www.insinkerator.com before calling AnswerLine™ TROUBLESHOOTING PROBLEM POSSIBLE CAUSE Water and steam spits forcefully from spout without turning on the dispenser faucet. • Unit is boiling. Water is not hot. • The unit is unplugged. May be normal during initial setup. WHAT TO DO • Activate faucet lever to release some water from the tank. • Adjust water temperature using dial on tank front.
Series 2200 Series 1100 Instant Hot Water Dispenser Owner’s Manual Installation, Care & Use Instalacion, cuidado & uso Installation, soin et utilisation 1.800.558.5700 www.insinkerator.com 44069 REV. A The Emerson logo is a trademark and service mark of Emerson Electric Co. Printed in USA © 2007 InSinkErator, a division of Emerson Electric Co. All Rights Reserved.